DeviceNet add-on module
5.
DeviceNet object
classes
5. DeviceNet object classes
5.1
Class code 0x01, identity
For class code 0x01, the following instance ID's are available:
Instance
Name
0
Class designator
1
Identity
For class code 0x01, the following instance attributes have been implemented:
Attribute
Access
1
Get
2
Get
3
Get
4
Get
5
Get
6
Get
7
Get
5.2
Class code 0x03, DeviceNet
For class code 0x03, the following instance ID's are available:
Instance
Name
0
Class designator
1
DeviceNet
For class code 0x03, the following class attributes have been implemented:
Attribute
Access
1
Get
For class code 0x03, the following instance attributes have been implemented
Attribute
Access
1
Set
2
Set
3
Set
4
Set
5
Get
8
Get
9
Get
Changing the MAC ID and Baud rate will not take effect until a reboot has occurred.
SFIDK.PS.023.C2.02
MAG
MASS
-
-
√
√
Name
Data type Description
Vendor ID
UINT
Device type
UINT
Product code
UINT
Revision
Struct of
USINT
Status
WORD
Serial number
UDINT
Product name
String
MAG
MASS
√
√
√
√
Name
Data type Description
Revision
UINT
Name
Data type Description
MAC ID
USINT
Baud rate
USINT
BOI
BOOL
Bus-off counter
USINT
Allocation
Struct
information
of Bytes
MAC ID
USINT
Switch Value
Baud rate
USINT
switch Value
Description
No attributes are shared between
the instances
Siemens Vendor Code = 862
Generic device = 0
MAG 6000 = 3
MASS 6000 = 4
Software version of DeviceNet option
MAG 6000: MAG 6000 DeviceNet
module
MASS 6000: MASS 6000 DeviceNet
module
Description
Revision of the DeviceNet object
Class
Node address
0: 125kBaud
1: 250kBaud
2: 500kBaud
Set: Reset counter
Get: Actual counter value
Returns the new MAC ID that will
be used after a reboot
Returns the new Baud Rate that
will be used after a reboot
17