The setup command facility prompts you for the data-link connection identifier (DLCI) number only if
Note
you specify none for the LMI type. If you accept the default or specify another Local Management
Interface (LMI) type, the DLCI number is provided by the specified protocol.
Enter the DLCI number for this interface [16]:
Do you want to map a remote machine's IP address to dlci? [yes]:
IP address for the remote interface: 2.0.0.2
Do you want to map a remote machine's IPX address to dlci? [yes]:
IPX address for the remote interface: 40.1234.5678
Serial interface needs clock rate to be set in dce mode.
The following clock rates are supported on the serial interface.
choose speed from above: [2000000]: 1200
Configure IP on this interface? [yes]:
IP address for this interface: 192.0.0.1
Subnet mask for this interface [255.0.0.0]:
Class A network is 2.0.0.0, 8 subnet bits; mask is /8
If Internetwork Packet Exchange (IPX) is configured on the router, the setup command facility prompts
you for the IPX map:
Do you want to map a remote machine's IPX address to dlci? [yes]:
IPX address for the remote interface: 40.0060.34c6.90ed
LAPB Encapsulation
The following is a sample configuration for Link Access Procedure, Balanced (LAPB) encapsulation:
lapb circuit can be either in dce/dte mode
Choose either from (dce/dte) [dte]:
ATM-DXI Encapsulation
The following is a sample configuration for asynchronous transfer mode data exchange interface
(ATM-DXI) encapsulation:
Enter VPI number [1]:
Enter VCI number [1]:
Do you want to map the remote machine's IP address to vpi and vci? [yes]:
Do you want to map the remote machine's IPX address to vpi and vci? [yes]:
SMDS Encapsulation
The following is a sample configuration for switched multimegabit data service (SMDS) encapsulation:
Enter smds address for the local interface: c141.5556.1415
We will need to map the remote smds station's address to the remote station's IP address
Enter smds address for the remote interface: c141.5556.1414
Do you want to map the remote machine's smds address to IP address? [yes]:
OL-5992-01
0
1200, 2400, 4800, 9600, 19200, 38400
56000, 64000, 72000, 125000, 148000, 500000
800000, 1000000, 1300000, 2000000, 4000000, 8000000
IP address for the remote interface: 6.0.0.1
IPX address for the remote interface: 40.0060.34c6.90ed
IP address for the remote interface: 192.0.0.1
Examples of Using the Setup Command Facility to Configure Interface Parameters
Basic Software Configuration Using the Setup Command Facility