GE GLM064 User Manual page 91

Pacsystems profinet managed industrial ethernet switches
Table of Contents

Advertisement

Appendix A. Command Language Interface (CLI)
A.3.3.63
rmon
Description
Syntax
Parameter
A.3.3.64
rmon alarm
Description
RMON Alarm
Syntax
rmon alarm <id> <oid_str> <interval> { absolute | delta } rising-threshold <rising_threshold> [
<rising_event_id> ] falling-threshold <falling_threshold> [ <falling_event_id> ] { [ rising |
falling | both ] }
Parameter
Name
id
ifInDiscards
fInErrors
ifInNUcastPkts
ifInOctets
ifInUcastPkts
ifInUnknownProtos
ifOutDiscards
ifOutErrors
ifOutNUcastPkts
ifOutOctets
ifOutUcastPkts
interval
absolute
delta
rising_threshold
rising_event_id
falling_threshold
falling_event_id
both
falling
rising
84
PACSystems PROFINET Managed Industrial Ethernet Switches User Manual
RMON
rmon {alarm | event}
Name
Description
alarm
Configure an RMON alarm
event
Configure an RMON event
Description
Alarm entry ID
The number of inbound packets that are discarded even the packets
are normal
The number of inbound packets that contained errors preventing them
from being deliverable to a higher-layer protocol
The number of broad-cast and multi-cast packets delivered to a
higher-layer protocol
The total number of octets received on the interface, including framing
characters
The number of uni-cast packets delivered to a higher-layer protocol
The number of the inbound packets that were discarded because of
the unknown or un-support protocol
The number of outbound packets that are discarded event the packets
is normal
The number of outbound packets that could not be transmitted
because of errors
The number of broad-cast and multi-cast packets that request to
transmit
The number of octets transmitted out of the interface, including
framing characters
The number of uni-cast packets that request to transmit
Sample interval
Test each sample directly
Test delta between samples
<-2147483648-2147483647> rising threshold value
<0-65535> Event to fire on rising threshold crossing
<-2147483648-2147483647> falling threshold value
<0-65535> Event to fire on falling threshold crossing
Trigger alarm when the first value is larger than the rising threshold or
less than the falling threshold (default)
Trigger alarm when the first value is less than the falling threshold
Trigger alarm when the first value is larger than the rising threshold
GFK-3030

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic086glm064Ic086glm082Ic086glm104Glm082Glm104

Table of Contents