GE GLM064 User Manual page 111

Pacsystems profinet managed industrial ethernet switches
Table of Contents

Advertisement

Appendix A. Command Language Interface (CLI)
A.3.8.6
sflow collector-port
Description
Collector UDP port
Syntax
sflow collector-port [ receiver <rcvr_idx_list> ] <collector_port>
Parameter
Name
collector_port
A.3.8.7
sflow sampling-rate
Description
Specifies the statistical sampling rate. The sample rate is specified as N to sample
1/Nth of the packets n the monitored flows. There are no restrictions on the value, but
the switch will adjust it to the closest possible sampling rate.
Syntax
sflow sampling-rate [ sampler <range_list> ] [ <1-4294967295> ]
Parameter
Name
< range_list >
<1-4294967295>
A.3.8.8
sflow timeout
Description
Receiver timeout measured in seconds. The switch decrements the timeout once per
second, and as long as it is non-zero, the receiver receives samples. Once the timeout
reaches 0, the receiver and all its configuration is reset to defaults.
Syntax
sflow timeout [ receiver <range_list> ] <0-2147483647>
Parameter
Name
< range_list >
<0-2147483647>
104
PACSystems PROFINET Managed Industrial Ethernet Switches User Manual
Description
<Collector Port : 1-65535> Port number
Description
Sampler instance
Sampling rate
Description
Sampler instance
Number of seconds.