Advertisement

LSA+® insertion tool
Preparing the connection cable
Connecting the cable
32 / 48
Installation
LSA+® insertion tool
Original KRONE insertion tool with solder-free
and stripping-free connection of the wires and
simultaneous trimming of the residual lengths.
Preparing the connection cable
Strip the connection cable approximately
6 cm.
Fold back approx. 1 cm of shielded
braiding completely and wrap it with
conductive adhesive textile tape.
Connecting the cable
Secure the connection cable at the point
of the wrapped shielded braiding in the
cable clamp [K].
The cable clamp must be screwed onto
the ground point [GND] of the circuit
board.
Clamp the wires to the terminal block
[ETH] using the insertion tool.