Keba KeContact P20 Installation Manual page 27

Hide thumbs Also See for KeContact P20:
Table of Contents

Advertisement

Opening the supply terminal
Connecting the wire
Closing the terminal
Installation
Opening the supply terminal
Push the screwdriver with moderate force
straight into the terminal until the wire
connector is completely open.
During pushing into the supply terminal,
the angle of the screwdriver is changing.
ATTENTION
Risk of breaking the terminal!
Do not pry the screwdriver up,
down or to the side!
Connecting the wire
Push the stripped connection wire into the
supply terminal as shown on the picture.
Closing the terminal
Pull the screwdriver completely out of the
supply terminal to close it.
Check the firm seating of the wire.
Connect the other wires in the same way.
27 / 48