Keba KeContact P30 Manual

Keba KeContact P30 Manual

Mid variants v 1.04
Hide thumbs Also See for KeContact P30:

Advertisement

Quick Links

KeContact
P30
Charging station
Manual for MID variants V 1.04
Translation of the original instructions

Advertisement

Table of Contents
loading

Summary of Contents for Keba KeContact P30

  • Page 1 KeContact Charging station Manual for MID variants V 1.04 Translation of the original instructions...
  • Page 2 Specifications are subject to change due to further technical developments. Details presented may be subject to correction. All rights reserved. Gewerbepark Urfahr, 4041 Linz, Austria, Phone: +43 732 7090-0, KEBA AG Headquarters: Fax: +43 732 7309-10, keba@keba.com For information about our subsidiaries please look at www.keba.com.
  • Page 3: Table Of Contents

    Read off device information and meter reading............Necessary checks.................... Trigger information display................Information display................... Calibrate the device ....................Test mode ......................Activate/deactivate test mode ................Affixing the calibration plate ................Appendix: Access protection..................Manual for MID variants V1.04 © KEBA...
  • Page 4: Introduction

    Introduction Introduction This manual is valid for the MID variants of KeContact P30. The pictured devices used in this manual are visual examples. The figures and explanations contained in this manual refer to a typical device design. The devices used by you may differ in their appearance.
  • Page 5: Purpose Of The Document

    Purpose of the document This document describes the MID-specific functions and features of the rele- vant variants of KeContact P30. The document is intended for charging sta- tion operators, calibration authorities or similar institutions. This document is an extension to the supplied manuals of the charging sta- tion.
  • Page 6: Not Contained In This Document

    Description of the operation of the charging station as an active power meter according to MID 2014/32/EU Further documentation Designation Target group ● End customer Operating Instructions ● Electricians Manuals and additional information are available on our website: www.keba.com/emobility-downloads Manual for MID variants V1.04 © KEBA...
  • Page 7: Description Of The Mid Device

    (certified energy meter) and are specifically indicated on the type plate. The associated type examination refers to the complete unit. Design ... Lower unit ... Terminal panel ... Connection panel ... Front part ... Terminal cover ... Connection panel cover ... Housing cover Manual for MID variants V1.04 © KEBA...
  • Page 8: Type Plate

    ... Technical data ... Marking of the approval ... Type examination number ... Accuracy class in accordance with EN 50470-1, -3 ... CE marking ... Public key information ... Production site ... Production date Manual for MID variants V1.04 © KEBA...
  • Page 9: Meter Seal

    If the meter seal is removed, you must assume that an attempt has been made to tamper with the meter. The charging station loses its conformity and may no longer be put into operation or used. Manual for MID variants V1.04 © KEBA...
  • Page 10: Overview Of Mid Variants

    6 m cable 5.5 m cable Device series c-series x-series WLAN x-series WLAN, 3G x-series WLAN, 4G x-series 3G x-series 4G Switching element 3-phase contactor Energy meter Active power meter, MID Authorization None RFID Manual for MID variants V1.04 © KEBA...
  • Page 11: Display

    "Operating Instructions". Brightness sensor The brightness sensor is located on the front of the charging station on the left below the LED bar. The information display can be triggered via the brightness sensor. Manual for MID variants V1.04 © KEBA...
  • Page 12 Display ... Brightness sensor Manual for MID variants V1.04 © KEBA...
  • Page 13: Active Power Meter

    ... Mains supply to the supply termi- ... Power tap for internal supply: Be- nals fore the active power meter ... Power measurement/active power ... Switching element meter ... Charging socket Backstop The meter has an electronic backstop. Manual for MID variants V1.04 © KEBA...
  • Page 14: Operational Readiness

    The active power meter is active in all available operating modes in which power can be delivered (including commissioning mode and test mode). See 6.1 Test mode for an overview of the operating modes. Manual for MID variants V1.04 © KEBA...
  • Page 15: Read Off Device Information And Meter Reading

    Start and end of a charging process ● Start or restart of the charging station For more information see "Operating Instructions". In addition, the information display can also be triggered via the brightness sensor. Manual for MID variants V1.04 © KEBA...
  • Page 16: Information Display

    Description Suitability of the firmware confirmed by type examination Firmware version Build version associated with the firmware version Checksum of the firmware Display of meter reading: Sum of total transmitted energy in kWh Manual for MID variants V1.04 © KEBA...
  • Page 17: Calibrate The Device

    Position of the pulse LED The pulse LED is located on the front of the charging station on the right be- low the LED bar..Pulse LED Manual for MID variants V1.04 © KEBA...
  • Page 18 On the output side, the test probes are inserted into the contacts of the charging socket. The pulse LED is evaluated with the evaluation unit. Manual for MID variants V1.04 © KEBA...
  • Page 19: Test Mode

    12 V DC residual current detec- activated deactivated deactivated tion Contactor monitoring Pulse LED Resolution of the total en- 0.1 kWh 0.1 Wh 0.1 Wh ergy display Active power meter (en- ergy meter) Manual for MID variants V1.04 © KEBA...
  • Page 20: Activate/Deactivate Test Mode

    DSW1.6 to ON DSW1.7 to OFF DSW1.8 to ON 4) Set the DIP switch for commissioning mode DSW2.8 to ON. 5) Switch on the supply voltage of the charging station. Test mode is activated. Manual for MID variants V1.04 © KEBA...
  • Page 21: Affixing The Calibration Plate

    5) Switch on the supply voltage of the charging station. Test mode is deactivated. Affixing the calibration plate The calibration plate must be affixed so that it is clearly visible at the bottom right of the front part..Calibration plate Manual for MID variants V1.04 © KEBA...
  • Page 22: Appendix: Access Protection

    Possible interactions with the charging station: ● Operating ● Configuring and diagnosing ● Connecting ● Checking/Calibrating The following table shows the powers of the individual target groups: Interaction Operating Configuring and diagnosing Connecting Checking/Calibrating Manual for MID variants V1.04 © KEBA...
  • Page 23 The charging station can be operated without tools. The charging station does not need to be opened for operation. This ensures that internal compo- nents can't be accessed when operating the charging station..Housing cover Manual for MID variants V1.04 © KEBA...
  • Page 24 Information None of the available configuration settings (in the connection panel or via the web interface) has any effect on the operational readiness or the mea- suring accuracy of the active power meter. Manual for MID variants V1.04 © KEBA...
  • Page 25 ... Front part ... Meter seal Checking/Calibrating The same procedures are necessary to check/calibrate the charging station as when connecting it. Manual for MID variants V1.04 © KEBA...