3.7

Location of probes

BERETTA STOR C combination storage cyl-
inders incorporate probe wells for fitting the
solar controller and boiler probes. Make sure
that these probes are inserted all the way.
b
To access the well for the domestic hot
water probe, you must remove the two
flange covers. (Drill a hole for the cable
if necessary).
b
Installers are responsible for all connec-
tions to the boiler or hot water generator.
Installers must ensure proper installation
and functioning in compliance with all
applicable legislation.
16
3.8

Initial start-up

It is essential to perform the following checks
before starting up or testing the functioning of
the combination storage cylinder. In particular,
check that:
- The supply cocks are all open in the domes-
tic water circuit.
- The water connections to the boiler and
solar heating system have been made cor-
rectly.
- The solar heating circuit has been correctly
flushed out and filled with water-glycol mix,
and all air has been bled out of the circuit.
b
The domestic hot water tank must be
filled and pressurised before the inertial
storage cylinder is filled.
Well for
DOMESTIC HOT
WATER PROBE
Well for
BOILER PROBE
Well for
AUXILIARY
PROBE
Well for
SOLAR
CONTROLLER
PROBE