Recycling/Disposal; Troubleshooting - Beretta STOR C 800 Installation Manual

Solar combination storage cylinder
Table of Contents

Advertisement

4 RECYCLING/DISPOSAL

4.1
Recycling/disposal
At the end of its useful life, the solar storage cylinder can be dismantled into its individual com-
ponents (cylinder body, insulation and external casing) for disposal or recycling in an environ-
mentally friendly manner.

5 TROUBLESHOOTING

PROBLEM
Little hot water
is produced
20
Water temperature is low
Replenishment times
are too long
CAUSE
The supply pressure is too high
The flow rate is too high
There are blockages or deposits
in the domestic hot water circuit
The pump is malfunctioning
The water temperature is low in
the heat generator or
solar heating system
There are problems with the
storage cylinder's thermostat
The pump is malfunctioning
There is lime scale or
sludge in the tank
There is air in the primary circuit
The water temperature in the
heat generator or solar heating
system is low
The filling pump is malfunctioning
There is air in the circuit
CORRECTIVE ACTION
Fit a pressure limiter
Fit a flow reducer
Check and clean as necessary
Check the pump
Check the setting and condition
of the thermostat
Check the setting and condition
of the thermostat
Check the pump
Check and clean as necessary
Bleed the circuit
Check the setting of the
thermostat
Check the pump
Bleed the circuit