Panel Menu
The Panel menu may be accessed in either of two ways: while operating using the LED Keypad
Option the Panel menu may be accessed via
EOI, press ESC from the Frequency Command screen.
The control settings of the Panel menu are effective for LED keypad control only if accessed via Direct
Access method
Command screen. Changes made to either of the Panel menus are not carried over to the other Panel
menu.
Using either method provides quick access to the following Panel menu parameters:
Direction — Forward or Reverse (see
Stop Pattern — The Decel Stop or Coast Stop settings determines the method used to stop the motor
when using the Stop|Reset key of the EOI. The Decel Stop setting enables the Dynamic Braking
system setup at
Stop setting allows the motor to stop at the rate allowed by the inertia of the load.
Note: The Stop Pattern setting has no effect on the Emergency Off settings of F603.
V/f Group — 1 of 4 V/f profiles may be selected and run. Each V/f profile is comprised of 4 user
settings: Base Frequency, Base Frequency Voltage, Manual Torque Boost, and Electronic
Thermal Protection. Expanded descriptions of these parameters may be found in the section titled
Direct Access Parameter Information in the G7 ASD Operation Manual.
Accel/Decel Group — 1 of 4 Accel/Decel profiles may be selected and run. Each of the Accel/Decel
profiles is comprised of 3 user settings: Acceleration, Deceleration, and Pattern. Expanded
descriptions of these parameters may be found in the section titled Direct Access Parameter
Information in the G7 ASD Operation Manual.
Feedback in Panel Mode — This feature enables or disables the PID feedback function.
Torque Limit Group — This parameter is used to select 1 of 4 preset positive torque limits to apply
to the active motor (of a multiple motor configuration). The settings of profiles 1 – 4 may be setup at
F441, F444, F446, and F448, respectively.

Monitor Mode

The Monitor mode allows the user to monitor motor performance variables, control settings, and
configuration data during motor operation. There are 46 items that may be monitored from this mode. The
items are listed and described below.
Note:
The Monitor mode is a read-only mode. The settings cannot be changed from the
Monitor mode. For information on how to change the values, see the section titled
Default Setting Changes in the G7 ASD Operation Manual.
Running Frequency — Displays the G7 Output Frequency.
Frequency Reference — Displays the Frequency Setpoint.
Output Current — Displays the Output Current as a percentage of the rated capacity of the G7.
Bus Voltage — Displays the Bus Voltage as a percentage of the rated capacity of the G7.
Output Voltage — Displays the Output Voltage as a percentage of the rated capacity of the G7.
Input Signal Status — Displays the status of the discrete input lines of the Control Terminal Strip.
Out1 Out2 FL — Displays the status of the discrete output lines of the Control Terminal Strip.
Timer — Displays the Cumulative Run Time in hours.
28
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
F008
and are effective for the LCD EOI control only if accessed via the Frequency
F008
F304
or the DC Injection Braking system setup at F250, F251, and F252. The Coast
F008
or if operating in the Local mode using the LCD
for further information on this setting).
G7 ASD Quick Start Guide