Philips CEM2100/00 Service Manual page 417

Mini system
Hide thumbs Also See for CEM2100/00:
Table of Contents

Advertisement

Characteristics
RFRP section (RFRPi → RFRP)
Voltage gain 1
Voltage gain 2
Voltage gain 3
Voltage gain 4
Detection frequency 1
(Note 7)
Detection constant 1
Operating reference
voltage 1
Operating reference
voltage 2
Output upper-limit
voltage
Permissible load
resistance
RFDC section (FPi1/FPi2 (FNi1/FNi2) → RFDC)
Detection frequency 1
(Note 7)
Detection constant 1
Operating reference
voltage 1
Operating reference
voltage 2
Output upper-limit
voltage
Output lower-limit
voltage
Permissible load
resistance
Note 7: The detection frequency values are for only reference purposes.
Test
Symbol
Circuit
G
V1RP
G
V2RP
RFRPI input amp gain
G
V3RP
G
V4RP
−3dB point with reference to
low-frequency side on the assumption
that RFRPI = 1.2 Vpp for V
f
1RP
output amplitude = 0dB for a 700 kHz
sine wave input.
RFRPI = 1.2 Vpp for V
slew rate (Cin > 1 μF) for a 5 kHz
T
1RP
rectangular wave input.
V
VRO reference, no input
OP1RP
VRO reference,
V
OP2RP
RFRPI = 1.2Vpp/700 kHz
V
GND reference
OHRP
R
LMRP
−3dB point with reference to
low-frequency side on the assumption
that RFDCI = 1.2 Vpp for V
f
1DC
output amplitude = 0dB for a 700 kHz
sine wave input.
RFDCI = 1.2 Vpp for V
slew rate (Cin > 1 μF) for a 5 kHz
T
1DC
rectangular wave input.
VRO reference,
V
FPI1/FPI2/FNI1/FNI2 open,
OP1DC
CMD: RFOOLDi = 00
VRO reference,
RFDCI = 1.2Vpp/350 kHz,
V
OP2DC
CMD: RFOOLDi = 00
V
GND reference
OHDC
V
GND reference
OLDC
R
LMDC
17
Test Condition
RFRPGi = 00
RFRPGi = 01
RFRPGi = 10
RFRPGi = 11
and
OP1RP
and
OP1RP
−1.15
and
OP1DC
and
OP1DC
−1.15
TC94B14MFG
Min
Typ.
Max
Unit
2.7
3.8
dB
4.8
5.7
50
kHz
90
V/ms
−0.75
V
0.3
1.0
2.9
3.1
V
10
15
20
kHz
14
V/ms
−0.75
V
0.2
0.55
2.7
3.0
V
0.5
0.8
20
25
2010-01-12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cem2100Cem2100/98

Table of Contents