Philips CEM2100/00 Service Manual page 133

Mini system
Hide thumbs Also See for CEM2100/00:
Table of Contents

Advertisement

High-frequency clock
XIN
XOUT
(a) Crystal/Ceramic
resonator
Figure 2-3 Examples of Resonator Connection
Note:The function to monitor the basic clock directly at external is not provided for hardware, however, with dis-
abling all interrupts and watchdog timers, the oscillation frequency can be adjusted by monitoring the pulse
which the fixed frequency is outputted to the port by the program.
The system to require the adjustment of the oscillation frequency should create the program for the adjust-
ment in advance.
XIN
XOUT
(Open)
(b) External oscillator
Page 11
Low-frequency clock
XTIN
XTIN
XTOUT
(c) Crystal
(d) External oscillator
T5CL8
XTOUT
(Open)