Mechanical Installation
3.2.3.1 Allowed Mounting Positions
3
3
Illustration 3.4 Allowed Mounting Positions - Standard
Applications
Illustration 3.5 Allowed Mounting Positions - Hygienic
Applications
12
®
VLT
Decentral Drive FCD 302
3.2.3.2 Mounting the Installation Box
ELECTRICAL HAZARD
Do not apply power to the unit at this stage, as this
could result in death or serious injury.
DAMAGE OR PERSONAL INJURY
Failure to tighten the 4 mounting screws can result in
personal injury or material damage.
Prerequisites:
1.
Illustration 3.6 FCD 302 Standalone Mounted with Mounting
Brackets
Danfoss A/S © 11/2016 All rights reserved.
CAUTION
CAUTION
Ensure that the strength of the mounting
location can support the unit weight.
Use the holes on the rear of the installation box
to fix the mounting brackets.
Use proper mounting screws or bolts.
For hygienic versions, use cable glands designed
to meet hygienic application requirements, for
example Rittal HD 2410.110/120/130.
®
Mount the VLT
Decentral Drive FCD 302
vertically on a wall or machine frame. For
hygienic versions, ensure that liquids drain off the
enclosure and orient the unit so the cable glands
are located at the base.
MG04F502