1 1
DESCRIPTION ON PARAMETER RELATED TO
GENERAL SEWING OPERATION
- Large patterns (SPS/E-5050, 8050)
※ The shadow area indicates factory-installed condition.
Function No. : 000
000. Jog En/Dis
1) DISABLE
Setting
Value
2) ENABLE
Function Name : Manual Operation En/Dis
It is to set moving of feed plate manually by using direction keys.
It is impossible for feed plate to move by using direction keys.
[ Contents ] It is impossible to make the feed plate move manually by using direction
keys in the sewing available mode.
[ Caution ] It is possible to make the feed plate move manually by using direction
keys without having relation to setup, under the condition of pattern
programming.
It you set up for "Disable" , you can' t use the Function No 001 ' Moving to
start position/the 2nd origin by manual drive' .
It is possible to make the feed plate move by using direction keys.
(Factory installed condition)
[ Contents ] It is possible to make the feed plate move manually by using direction
keys in the sewing available mode.
[ Caution ] It is only possible when upper feed plate is down.