5. MAINTENANCE AND TROUBLESHOOTING
No.
Item name
1
Port tabs
Select a tab to show the corresponding port details in the display area.
• Serial Port 1/2(NMEA)*: Shows incoming NMEA data for port 1 or 2.
• Serial Port 3(CIF)*: Shows incoming CIF data for port 3.
• Network: Shows incoming NETWORK port data.
*: The bracket indication (NMEA/CIF) changes according to the setting for [Data
Type].
2
[Refresh]
Select to update the display area.
button
3
Display
Shows the incoming data details for the selected port.
area
4
[Settings]
Access the output settings window for the selected port.
button
Note: This button is not available for the [Network] tab.
• [Data Type]: Set the output sentence type
• [NMEA Format]: Set the NMEA format to use for data output.
• [Output Data]*: Where [TLL Output] is set to [FURUNO-TLL], select the infor-
• [TLL Output]*: Select which TLL data to output. The data will be output when
• [Baud Rate]*: Set the data transfer speed. Available options are listed below.
• [Start Bit]: Shows the text size of the data to be output.
• [Data Length]: Shows the length of the data to be output.
• [Stop Bit]: Shows the stop bit size.
• [Parity]: Shows the data parity.
*: Where [NMEA Format] is set to [Squid-Fishing], these options are fixed.
To close the [Communication Port Monitor], select the [Close Window] icon (
the top-right corner of the window.
Note 1: When [CIF] is selected as the [Data Type], only [Baud Rate] can be changed.
All other items are gray and not selectable. (See above figure for reference.)
Note 2: Latitude, longitude and water temperature output requires connection to the
appropriate sensors.
5-8
[NMEA]: Output sentences in NMEA format.
[CIF]: Output sentences in CIF format.
Available options are: [Ver1.5], [Ver2.0], [Ver3.0] or [Squid-Fishing]).
mation to output. More than one item can be selected from [Depth], [Tempera-
ture], [Hardness] or [Fish Size].
Note: [Fish Size] is only available where [Baud Rate] is set to [38400bps].
a TLL line is inscribed. (Requires [NMEA Format] → [Ver3.0] to output.)
[Off]: No TLL data is output.
[TLL]: Only latitude and longitude are output.
[FURUNO-TLL]: Latitude, longitude and items selected at [Output Data] are
output. (Requires connection to a FURUNO-TLL compatible device.)
Where [Data Type] is set to [NMEA]: 600, 4800, 38400 (bps).
Where [Data Type] is set to [CIF]: 600, 1200, 2400, 4800 (bps).
Description
Available settings
change depending
on the setting
selected for [Data
Type].
[ NMEA ]
[ CIF ]
) at