Panasonic Industrial Devices Sunx Co., Ltd - Panasonic SF4B-F31G(V2) Instruction Manual

Light curtain type4 heavy-duty
Table of Contents

Advertisement

● Auxiliary output switching function (non-safety output)
The following outputs are switchable as the auxiliary output.
0. Negative logic of the control output (OSSD 1 / 2) (factory setting)
1. Positive logic of the control output (OSSD 1 / 2)
2. For emission: output ON, For non-emission: output OFF
3. For emission: output OFF, For non-emission: output ON
4. For unstable incident light: OFF (Note 1)
5. For unstable incident light: ON (Note 1)
6. For muting: ON
7. For muting: OFF
8. For light reception: ON, For light blocked: OFF (Note 2)
9. For light reception: OFF, For light blocked: ON (Note 2)
Notes: 1) The output cannot be used while the fix blanking function, floating blanking function or the muting func-
tion is activated.
2) This device outputs the light received / blocked state under activating the auxiliary output switching
function using the handy controller irrespective of activating other functions: fixed blanking function,
floating blanking function and muting function.
<e.g.>
In case of activating the fixed blanking function, the control output (OSSD 1 / 2) becomes ON with the
shielded object existed in the setting range and other ranges are in light receiving status.
If the auxiliary output switching function activates in No. 8 output, this device becomes OFF because
the sensor itself detects the object.
● Interlock setting changing function
It is selectable one interlock state among the following three interlock settings
• Start / Restart interlock
The device goes into the interlock state after the power is turned ON, or when the light is
blocked.
The factory setting is start / restart interlock.
• Start interlock
The device goes into the interlock state when the power supply is turned ON. Once this
interlock is reset, the device does not go into the interlock state.
• Restart interlock
The device does not go into the interlock state when turning ON the power supply. Only
when the control output (OSSD 1 / 2) becomes ON and the light is blocked after the power
is turned ON and this device receives the light, the device goes into the interlock state.
● External device monitor setting changing function
The setting of the external device monitor is changeable.
1. Allowable time for response time: 100 to 600ms (Unit: 10ms)
Factory setting is 300ms.
2. The external device monitor function can be selected to valid or invalid.
The factory setting is set to valid for the external device monitor function.
72