<For NPN output>
Gray cable
Gray cable
with black line
Interlock function
External device monitor function Invalid
Auxiliary output
The device output is selected depending on the connecting state of the output polarity setting wire
(shield). Incorrect wiring may cause the lockout state.
* Symbols
Switch S1
0 to +1.5V (source current 5mA or less): Emission, Open: Emission halt
K1, K2: Safety relay unit etc.
Note: The circuit diagram shown above is for 12-core cable to be used. For 8-core cable, red, yellow, gray, gray /
black, sky-blue / white, sky-blue / black, there is no lead wire.
50
(Gray) Interference prevention +
(Gray / Black) Interference prevention -
(Red) Muting lamp output
(Yellow) Override input
(Pale purple) Interlock setting input
(Brown) +V
(Shield) Output polarity setting wire
(Pink) Emission halt input / Reset input
(Blue) 0V
(Yellow-green / Black) Auxiliary output
(Orange) Synchronization +
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
(Orange) Synchronization +
(Yellow-green) External device monitor input
(Brown) +V
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Shield) Output polarity setting wire
(Blue) 0V
(Sky-blue / White) Muting input A
(Sky-blue / Black) Muting input B
(Gray / Black) Interference prevention -
(Gray) Interference prevention +
Invalid (Auto-reset)
Cannot be used
K1
K2
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
+
24V DC
±10 %