Panasonic SF4B-F31G(V2) Instruction Manual page 13

Light curtain type4 heavy-duty
Table of Contents

Advertisement

<Display section>
Emitter
Beam-axis alignment indicator
[RECEPTION]
Operation indicator [OSSD]
Incident light intensity indicator [STB.]
Fault indicator [FAULT]
Digital error indicator
PNP indicator [PNP]
NPN indicator[NPN]
Emission intensity control indicator
[CTRL]
Emission halt indicator [HALT]
Description
When device top receives light: lights up in red
When device top end receives light: blinks in red
A
When control output (OSSD 1 / 2) is ON:
When device upper middle receives light: lights up in red
Beam-axis
B
When control output (OSSD 1 / 2) is ON: lights up in green
alignment indicator
(Red / Green)
When device lower middle receives light: lights up in red
C
[RECEPTION]
When control output (OSSD 1 / 2) is ON: lights up in green
When device bottom receives light: lights up in red
When device bottom end receives light: blinks in red
D
When control output (OSSD 1 / 2) is ON:
Lights up while device operation is as follows
[sequential operation control output (OSSD1 / 2)]
Operator indicator
When control output (OSSD 1 / 2) is OFF:
(Red / Green) [OSSD]
(Note 1)
When control output (OSSD 1 / 2) is ON:
When sufficient light is received
(Incident light: 130% or more) (Note 2): lights up in green
Incident light intensity
When stable light is received
indicator
(Incident light: 115 to 130%) (Note 2): OFF
(Orange / Green)
When unstable light is received
[STB.]
(Incident light : 100 to 115%) (Note 2): lights up in orange
When light is blocked: OFF (Note 3)
Fault indicator (Yellow)
When fault occurs in the device:
[FAULT]
When device is lockout, error contents are indicated.
Digital error indicator
When the sensors are connected in paral-
(Red)
lel, the bottom of the digital error indicator
on the slave side sensors lights up in red.
PNP indicator (Orange)
When PNP output is set: lights up
[PNP]
NPN indicator (Orange)
When NPN output is set: lights up
[NPN]
Emission intensity
When light is emitted under short mode:
control indicator
(Orange) [CTRL]
When light is emitted under normal mode: OFF
Emission halt indicator
When light emission is halt: lights up
(Orange) [HALT]
When light is emitted: OFF
Notes: 1) Since the color of the operation indicator changes according to ON / OFF status of the control output
(OSSD 1 / 2), the operation indicator is marked as "OSSD" on the device.
2) The threshold where the control output (OSSD 1 / 2) changes from OFF to ON is applied as "100%
incident light intensity".
3) "When light is blocked" refers to the status that there exists any object blocking light in the sensing area.
4) The blanking function is set by using the handy controller (SFB-HC) (optional). Please purchase the handy
controller separately.
5) The description given in [ ] is marked on the device.
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
Beam-axis
alignment
indicator
[RECEPTION]
Bottom end
Function
lights up in green
lights up in green
lights up in red
lights up in green
lights up or blinks
lights up
Receiver
Top end
Incident light intensity indicator [STB.]
Interlock indicator [INTERLOCK]
Description
When device top receives light: lights up in red
When device top end receives light: blinks in red
A
When control output (OSSD 1 / 2) is ON:
When device upper middle receives light: lights up in red
Beam-axis
B
When control output (OSSD 1 / 2) is ON: light up in green
alignment indicator
(Red / Green)
When device lower middle receives light: lights up in red
C
[RECEPTION]
When control output (OSSD 1 / 2) is ON: lights up in green
When device bottom receives light: lights up in red
When device bottom end receives light: blinks in red
D
When control output (OSSD 1 / 2) is ON:
When control output (OSSD 1 / 2) is OFF:
OSSD indicator
(Red / Green) [OSSD]
When control output (OSSD 1 / 2) is ON:
When sufficient light is received
(Incident light: 130% or more) (Note 2): lights up in green
Incident light intensity
When stable light is received
indicator
(Incident light: 115 to 130%) (Note 2): OFF
(Orange / Green)
When unstable light is received
[STB.]
(Incident light : 100 to 115%) (Note 2): lights up in orange
When light is blocked: OFF (Note 3)
Fault indicator (Yellow)
When fault occurs in the device:
[FAULT]
When device is lockout, error contents are indicated.
Digital error indicator
When the sensors are connected in paral-
(Red)
lel, the bottom of the digital error indicator
on the slave side sensors lights up in red.
PNP indicator (Orange)
When PNP output is set: light up
[PNP]
NPN indicator (Orange)
When NPN output is set: lights up
[NPN]
When blanking function is used:
Function setting indicator
(orange) [FUNCTION]
When connecting the handy controller: brinks
When device is interlocked: lights up
Interlock indicator
Other cases: OFF
(Yellow) [INTERLOCK]
Beam-axis alignment indicator
[RECEPTION]
OSSD indicator [OSSD]
Fault indicator [FAULT]
Digital error indicator
PNP indicator [PNP]
NPN indicator [NPN]
Function setting indicator
[FUNCTION]
Function
lights up in green
lights up in green
lights up in red
lights up in green
light up or blinks
lights up (Note 4)
13

Advertisement

Table of Contents
loading

Table of Contents