Panasonic SF4B-F31G(V2) Instruction Manual page 52

Light curtain type4 heavy-duty
Table of Contents

Advertisement

<For NPN output>
Gray cable
Gray cable
with black line
Interlock function
External device monitor function Valid
Auxiliary output
The device output is selected depending on the connecting state of the output polarity setting wire
(shield). Incorrect wiring may cause the lockout state.
* Symbols
Switch S1
0 to +1.5V (source current 5mA or less): Emission, Open: Emission halt
Switch S2
The muting input, the override input
0 to +1.5V (source current 5mA or less): Valid, Open: Invalid
K1, K2: External device ( Forced guided relay or magnetic contactor)
Note: The incandescent lamp with 3 to 10W shall be connected to the muting lamp output. If the muting lamp is not
connected, the muting function does not operate.
52
(Gray) Interference prevention +
(Gray / Black) Interference prevention -
(Pale purple) Interlock setting input
(Brown) +V
(Yellow-green / Black) Auxiliary output
(Shield) Output polarity setting wire
(Yellow) Override input
(Pink) Emission halt input / Reset input
(Red) Muting lamp output
(Blue) 0V
(Orange) Synchronization +
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
(Orange) Synchronization +
(Yellow-green) External device monitor input
(Brown) +V
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Shield) Output polarity setting wire
(Sky-blue / White) Muting input A
(Sky-blue / Black) Muting input B
(Blue) 0V
(Gray / Black) Interference prevention -
(Gray) Interference prevention +
Invalid (Auto-reset)
Can be used
Load
*S1
(Note 1)
K1
K2
*S2
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
+
24V DC
±10 %
-
*S2
K1
K2
*S2