1. Specifications

Model
Power supply
Ambient temp in cooling
Ambient temp in heating
Rated input (Whole units)
Rated current (Whole units)
Compressor
Outdoor fan motor
Outdoor fan
Outdoor coil
Outdoor air flow
Sound pressure level
Outdoor unit
Model
Type
Brand
Quantity
Capacity
Input
Crankcase heater
Refrigerant oil type
Refrigerant oil charge
Model
Type
Quantity
Brand
Insulation class
Safe class
Input
Output
Rated current
Material
Type
Quantity
Diameter
Height
Number of rows
Tube pitch(a)×row pitch(b)
Fin spacing
Fin type
Tube outside diameter
Tube type
Length × height
Number of circuits
Net dimension(W×D×H)
Packing
dimension(W×D×H)
Net/Gross weight
\
V, Ph, Hz
°C
°C
W
A
\
\
\
\
kW
kW
W
\
mL
\
\
\
\
\
\
W
W
A
\
\
\
mm
mm
\
mm
mm
\
mm
\
mm
\
m
3
/h
dB(A)
mm
mm
kg
6
ASDH-96AI
380-415V~, 3Ph, 50Hz
-15~48
-15~24
11,700
16
LNB53FCAMC
Rotary
MITSUBISHI
1
16.86
5.2
25
FV50S
1700 + 1500
WZDK170-38G-1
DC
2
Panasonic
E
IP × 4
250(up)/185(down)
200(up)/150(down)
1.7(up)/1.4(down)
Plastic
Axial fan
2
560
170
2
21 × 19.4
1.5
Hydrophilic fin
Ф7
Inner groove tube
1080 x 756
18
9800
59
1120×1558×528
1270×1720×565
147/163