1.2 Wired controller outlook

1.3 Operation instructions

1) Remote signal receiving function:
the wired controller can be a remote signal receiving device, it is possible to use the wireless remote controller
to control the air conditioner through the wired controller when the system have been powered on.
Note:
The wired controller will not receive the swing controlling instruction. For the indoor unit with swinging function, you
can directly use the wireless remote controller to control swinging through the display panel of the indoor unit, or use the
swing button on the wired remote controller to control the indoor unit for swinging.
2) On and off the air conditioner:
Press the
On/Off button to control the indoor unit on and off status.
When the unit is turned off, press the
On/Off button, the unit will be turned on and the operating icon
lights up.
When the unit is turned on, press the
On/Off button, the unit will be turned off the operating icon
lights off.
3) Set the operating mode
Press the mode button
to set the operating mode, after each button press the operating mode will circle
as follow: