USER'S MANUAL HIGH STATIC PRESSURE DUCT SERIE ASDH-96AI...
Page 2
“Original instructions” IMPORTANT NOTE: Read this manual ca r efully befo r e installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
CONTENTS PAGE Where oil gas, salty air(near the coast), caustic gas(the sulfide in hotspring) exist,otherwise it may damage the unit and shorten the life span of the manchine. If the PRECAUTIONS...................1 situations above can’t be avoided, choose a anticorrosive PARTS NAMES..................2 model.
grounded and that the earth wire is not connected to gas or Contact you local government for information regarding the water pipe, lightning conductor or telephone earth wire. collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get In order to avoid injury, do not remove the fan guard of into the food chain, damaging your health and well-being.
Fuse Power switch Type specification supply specification Indoor unit Electrical control box Outdoor 380-415V 3N~ ASDH-96AI unit 50Hz Indoor 220-240V~ ASDH-96AI unit 50Hz NOTE Air return duct(option) Air outlet pipe, mute box(option) Do not cut off the ground wire of the main power switch in any circumstance.
6. OPERATION PRECAUTIONS NOTE Read this operation manual carefully before operating the unit. Grasp The indoor relative humidity should be lower than 80%. If the air the key points in the manual, and seek help from the con distributor conditioner works in an environment with a relative humidity for any question.
8. MAINTENANCE & UPKEEP Check whether the ground wire is connected properly. Check whether the condensate water is discharged normally. 8.1 Importants (Cooling operation season) Check whether the insulation work of refrigerant circuit and Only the professionals can perform repair. ventilating duct is on sound status.
10. PHENOMENA NOT ATTRIBUTABLE TO In order to prevent frosting of the indoor heat exchanger, the air conditioner shifts to the air supply mode automatically, and FAULTS OF AIR CONDITIONER resumes to cooling mode in a short time. When the room temperature decreases to the set temperature, the air conditioner will shut down the compressor automatically, The following phenomena do not indicate exception of air and shifts to the air supply status.
12. FAULTS OF REMOTE CONTROLLER Detect leak, and fill the The refrigerant is AND CAUSE refrigerant of a correct excessive or quantity deficient. The unit keep Make a vacuum again Air or noncondens- starting up Before requesting for maintenance or repair, inspect the and fill the refrigerant.
Table 12-5 No sound of receiving signal cause Symptom Check item When the ON/OFF button When Align the signal is pressed, check pressing the transmiting part of the whether the signal ON/OFF remote controller with transmitting part of the button, the receiving part of the remote controller is the air...
Page 12
SINCLAIR CORPORATION Ltd. 1-4 Argyll St. London W1F 7LD Great Britain www.sinclair-world.com This product was manufactured in China (Made in China). REPRESENTATIVE SINCLAIR EUROPE spol. s r.o. Purkynova 45 612 00 Brno Czech Republic TECHNICAL SUPPORT NEPA spol. s r.o. Purkynova 45...