Imagine communications Selenio 6800 Installation And Operation Manual page 85

Audio multiplexers
Table of Contents

Advertisement

Appendix A: Audio Bit Manipulation
Table A-2. Channel Status (C-Bits) Data Description (Continued)
Byte
Bit
Function
4
3 to 6
[0000] Not indicated
[1000] 24 kHz
[0100] 96 kHz
[1100] 192 kHz
[1001] 22.05 kHz
[0101] 88.2 kHz
[1101] 176.4 Hz
[1111] User defined
4
7
[0] Sample frequency not scaled
[1] Sample frequency scaled by 1/1.001
5
0 to 7
Reserved
6 to 9
0 to 7
Alphanumeric channel origin data
10 to 13
0 to 7
Alphanumeric channel destination data
14 to 17
0 to 7
Local sample address code
18 to 21
0 to 7
Time-of-day sample address code
22
0 to 3
Reserved
22
4
Bytes 0 to 5 reliability flag
72
RX
TX
Remarks
• RX ignores bits
N
Y
• TX sets bits to [0000]
• RX ignores bits
N
Y
• TX sets bits to [0]
• RX ignores bits
N
Y
• TX sets bits to
[00000000]
• RX ignores bits
S
Y
• TX passed bits
unmodified
• RX ignores bits
S
Y
• TX passed bits
unmodified
• RX ignores bits
S
Y
• TX passed bits
unmodified
• RX ignores bits
S
Y
• TX passed bits
unmodified
• RX ignores bits
N
Y
• TX passed bits
unmodified
• RX ignores bits
N
Y
• TX passed bits
unmodified
HMX6800+BC8 Installation and Operation Manual