Imagine communications Selenio 6800 Installation And Operation Manual page 76

Audio multiplexers
Table of Contents

Advertisement

Table 3-13. Alarm Definitions—HMX6800+BC8
Alarm Name
Loss of SDI
Video Standard Mismatch Reports that a mismatch
Unsupported Video
Standard
Group (1 - 4) Append
Embedding Error
Group (1 - 4) Overwrite
Embedding Error
AES (1 - 8) In Missing
HMX6800+BC8 Installation and Operation Manual
Table 3-13
describes the specific alarms for the HMX6800+BC8. You
can only identify specific alarms using a software control application.
Alarm Description
Reports that active SD/
HD-SDI is absent
has occurred between the
set and detected input
video standards
Reports that the detected
input video standard is
unsupported
Reports that the embedder
is unable to append the
specified audio group due
to the pre-existence of that
audio group
Reports that the embedder
is unable to overwrite the
specified audio group due
to a lack of that audio
group existing in the input
SDI
Reports that the specified
AES input is missing
Alarm Option Default Settings
Enable/
Priority
Disable
Enabled
9
Enabled
8
Enabled
8
Enabled
6
Enabled
6
Enabled
1
Chapter 3: Operation
Trigger
Clear
1 sec
2 sec
1 sec
2 sec
1 sec
2 sec
2 sec
2 sec
2 sec
2 sec
2 sec
2 sec
63