  • Page 1 Installation and Operation Manual Selenio 6800™ ACO6800+ Dual AES Automatic Change Over Revision: A 175-100470-00 Delivering the Moment...
  • Page 2 Imagine Communications reserves the right, without notice to make such changes in equipment, design, specifications, components, or documentation as progress may warrant to improve the perfor- mance of the product.
  • Page 3 ACO6800+AES Dual AES Automatic Change Over Installation and Operation Manual Edition A July 2013...
  • Page 4: Table Of Contents

    Contents Preface ..........................v Manual Information .......................v Purpose ........................v Audience ........................v Revision History ......................v Writing Conventions ....................v Obtaining Documents ....................vi Unpacking/Shipping Information ................vi Unpacking a Product ....................vi Product Servicing ....................... vi Returning a Product ....................vi Restriction on Hazardous Substances (RoHS) Directive ..........vii Waste from Electrical and Electronic Equipment (WEEE) Directive ......
  • Page 5 Changing Parameter Settings ..................8 Recalling Default Parameter Settings ................8 Changing Parameter Settings Using CCS Software ............. 9 Reading Software and Hardware Versions ..............9 Audio Configuration ....................10 Switch Settings with the 2X4 Work Mode ..............10 Switch Setting with 1X8 Work Mode ............... 11 Sample Scenario One: Parameter Settings ..............
  • Page 6: Preface

    Preface Manual Information Purpose This manual details the features, installation, operation, maintenance, and specifications for the ACO6800+AES Dual AES Automatic Change Over. Audience This manual is written for engineers, technicians, and operators responsible for the installation, setup, and/or operation of the ACO6800+AES Dual AES Automatic Change Over.
  • Page 7: Obtaining Documents

    Preface Table P-2 Writing Conventions (Continued) Term or Description Convention hyperlink Indicates a jump to another location within the electronic document or elsewhere Internet Indicates a jump to a website or URL address Indicates important information that helps to avoid and troubleshoot problems Obtaining Product support documents can be viewed or downloaded from our website.
  • Page 8: Restriction On Hazardous Substances (Rohs) Directive

    ACO6800+AES Installation and Operation Manual Restriction on Hazardous Substances (RoHS) Directive Directive 2002/95/EC—commonly known as the European Union (EU) Restriction on Hazardous Substances (RoHS)—sets limits on the use of certain substances found in electrical and electronic equipment. The intent of this legislation is to reduce the amount of hazardous chemicals that may leach out of landfill sites or otherwise contaminate the environment during end-of-life recycling.
  • Page 9: Safety

    viii Preface Safety Carefully review all safety precautions to avoid injury and prevent damage to this product or any products connected to it. If this product is rack-mountable, it should be mounted in an appropriate rack using the rack-mounting positions and rear support guides provided. To protect a frame from circuit overloading, connect each frame to a separate electrical circuit.
  • Page 10: Chapter 1 Introduction

    Introduction Product Description The ACO6800+AES Dual AES Automatic Change Over supports both 2X4 and 1X8 AES/EBU distribution modes, with four copies of the input signal. The module supports audio sampling frequencies from 30 kHz to 192 kHz, and is available in balanced, unbalanced, and unbalanced loopthrough versions.
  • Page 11: Aco6800+Aes+Cdl

    Chapter 1 Introduction ACO6800+AES+CDL Same features as ACO6800+AES+CD  Additionally supports one passive loop per channel on back module  Other Common Features: Remote monitoring via SNMP using Navigator or Web Server control  Support sample frequency indication for standard AES signal ...
  • Page 12: Back Module

    ACO6800+AES Installation and Operation Manual Back Module ACO6800+AES+CD ACO6800+AES+CDL ACO6800+AES+BD Figure 1-1 ACO6800+AES Back Modules Signal Flow Driver Unbalanced > Balanced AES Out A1 Transformer Driver Unbalanced > Balanced > AES In A Balanced Unbalanced Input Buffer AES Out A2 Transformer Transformer Driver...
  • Page 13 Chapter 1 Introduction Driver AES Out A1 Driver AES In A Input Buffer AES Out A2 Driver AES Out A3 Detection Driver AES Out A4 Control Switch Driver Control AES Out B1 Driver Detection AES Out B2 Driver AES In B Input Buffer AES Out B3 Driver...
  • Page 14: Chapter 2 Installation And Operation

    Installation and Operation Unpacking the Module Before you install modules, perform the following: Check the equipment for any visible damage that may have occurred during transit.  Confirm receipt of all items on the packing list.  Note: Contact your Customer Service representative if parts are missing or damaged. Remove the anti-static shipping pouch, if present, and all other packaging material.
  • Page 15: Maximum Frame Power Ratings

    Chapter 2 Installation and Operation Prior to power-up, set the jumper for the correct Remote/Local configuration. Place a jumper on pins 1 and 2 to set the module for Remote control, or pins 2 and 3 to set the module for Local control. Pins: 3 Figure 2-2 Jumper CJ3/CJS3 for Remote and Local Control The Local setting locks out external control panels and allows card-edge control only;...
  • Page 16: Installing Aco6800+Aes Modules

    ACO6800+AES Installation and Operation Manual Installing ACO6800+AES Modules ACO6800+AES products can be installed in an FR6822+QXFE frame, or an FR6822+F frame containing a 6800+ETH module, except in slots 6 and 14. When installing both front and rear modules together, ensure that the back module is installed first before plugging in the front module.
  • Page 17: Changing Parameter Settings

    Chapter 2 Installation and Operation Changing Parameter Settings For best results, use a software control (serial/local or Ethernet/remote) to aid in viewing, setting, and confirming parameter values Follow these steps to change the parameter settings: Rotate the mode select rotary switch (hex switch) to 0. Once the hex switch is set to 0, toggle the navigation switch up or down to select a bank.
  • Page 18: Changing Parameter Settings Using Ccs Software

    ACO6800+AES Installation and Operation Manual Changing Parameter Settings Using CCS Software Before using CCS Navigator to change your module’s parameter settings, you must discover the module. Discovering the Module Using CCS Software To discover your module, your Navigator software must be in Build mode. If the Discovery window is not open, click Tools >...
  • Page 19: Audio Configuration

    Chapter 2 Installation and Operation Audio Configuration The ACO6800+AES operates in one of two DA Work Modes: 2x4 mode (dual independent one input/ four output DA)  1x8 mode (one input/ eight output DA)  (-CDL versions are effectively 2x3 and 1x6 because one output in each channel is a loopthrough.) When you select either one of the DA Work Modes, the available options change in the parameter tree.
  • Page 20: Switch Setting With 1X8 Work Mode

    ACO6800+AES Installation and Operation Manual Figure 2-5 AES x Alarm Switch Level Set the option you require for the AES x Manual Switch, which controls the output source. Figure 2-6 AES x Manual Switch Switch Setting with 1X8 Work Mode To make settings in the 1X8 Work Mode, follow these steps.
  • Page 21 Chapter 2 Installation and Operation Figure 2-9 AES Alarm Switch Level Set the option you require for the AES Manual Switch, which controls the output source. Figure 2-10 AES Manual Switch Set the AES Alarm Switch Mode. In automatic mode, input A is the primary channel and input B is the backup channel. Whenever a change over condition from input A is satisfied, the output source is from input A.
  • Page 22: Sample Scenario One: Parameter Settings

    ACO6800+AES Installation and Operation Manual AES x Alarm Switch Level The AES x Alarm Switch Level parameter sets the level for the alarm auto switch, in a range from 1 to 10. Under preset conditions, when an alarm belonging to channel x has been triggered, the module will change over to the alternate channel.
  • Page 23: Sample Scenario One: Chain Of Events

    Chapter 2 Installation and Operation Sample Scenario One: Chain of Events Table 2-4 Sample Scenario One: Chain of Events Event Result 1. At the start, input A and input B Output is A (A is the primary channel in 1x8 mode) are both present 2.
  • Page 24: Sample Scenario Two: Chain Of Events

    ACO6800+AES Installation and Operation Manual Sample Scenario Two: Chain of Events Table 2-6 Sample Scenario Two: Chain of Events Event Result 1. At the start, input A and Output is A (A is the primary channel in 1x8 mode) input B are both present 2.
  • Page 25: Aco6800+Aes Control Parameters

    Chapter 2 Installation and Operation ACO6800+AES Control Parameters Note: The sequence of options listed in the Value/Range column mirrors the sequence achieved when you move the Navigation Toggle switch up. The On/Off combinations of the control LEDs on the card edge indicate the active bank number.
  • Page 26 ACO6800+AES Installation and Operation Manual Table 2-7 ACO6800+AESD Parameters Group Parameter Name Function Options Disable  AES A and AES B 1, 5 Sets the 2X4 output source when a Manual Switch 1, 8 channel is switched manually Input A ...
  • Page 27: Leds And Alarms

    Chapter 2 Installation and Operation LEDs and Alarms Monitoring LEDs Figure 2-14 shows the location of the monitoring LEDs and the Remote/Local jumper on the module. Module Status LEDs Control LEDs Monitoring LEDs Figure 2-14 Location of Card-Edge LEDs Table 2-8 ACO6800+AES Monitoring LEDs Indicators Name Description Color Indication...
  • Page 28: Module Status Leds

    ACO6800+AES Installation and Operation Manual Module Status LEDs The ACO6800+AES module does not have any card-edge alarms. Instead, module status LEDs on the corner of the module light up if an error is detected. Note: If the LED is flashing red, please contact your Customer Service representative. Table 2-9 Module Status LED Descriptions LED Color Meaning...
  • Page 29 Chapter 2 Installation and Operation...
  • Page 30: Chapter 3 Specifications

    Specifications Audio Input Table 3-1 AES Balanced Input Specifications Item Specification Connector Leitch Audio 3M Sensitivity <200 mV ± Impedance 110Ω 20% (0.1 to 24 MHz) Maximum Input Signal 7 V (pk-to-pk) Common Mode Rejection 0 V to 7 V (0 kHz to 20 kHz) Input audio rate 30 kHz to 192 kHz* *At 192 kHz sample rate, the input level should be >+500 mV pk-to-pk and input rise/fall...
  • Page 31: Audio Output

    Audio Output AES Balanced Output Specification Table 3-3. Item Specification Type Balanced, transformer coupled Connector Leitch Audio 3M Standard AES 3 ± Impedance 110Ω 20% (0.1 to 24 MHz) Signal Amplitude 2 to 7 V pk-to-pk into 110Ω load Audio rate 30 kHz to 192 kHz Jitter <0.025 UI...
  • Page 32: Propagation Delay

    Dual AES Automatic Change Over Installation and Operation Manual Propagation Delay Table 3-5 Propagation Delays Sampling Rate Delay µ 48 kHz µ 96 kHz µ 192 kHz Power Consumption Table 3-6 Power Consumption ACO Module Power Consumption Dual AES Automatic Change 2.4 W Over (BD) Dual AES Automatic Change...
  • Page 34: Appendix A Communication And Control Troubleshooting Tips

    Communication and Control Troubleshooting Tips Software Communication Problems Problem The frame is powered up, but the module does not communicate with CCS Navigator or the web GUI interface. Solutions Ensure you have specified the proper module slot.  See your 6800+ Frame Installation and Operation Manual for more information about slot identification.
  • Page 35 Appendix A Communication and Control Troubleshooting Tips Problem The IP address of the frame has been forgotten. Solution Follow this procedure: Remove the ETH6800+ module from the frame. Select DIP switch 2 on the ETH6800+ module and slide the tab to the forward position. This sets the ETH6800+ module to its default IP address of 192.168.100.250.
  • Page 36: Hardware Communication Problems

    ACO6800+AES Installation and Operation Manual Problem CCS software sees the frame, but does not find all of the modules. Solutions Remove any legacy 6800 series products.  Plug your modules in before starting the discovery.  Start your discovery after the frame and all modules have fully powered up. ...
  • Page 37 Appendix A Communication and Control Troubleshooting Tips Problem The module does not seem to work. Solutions Ensure the correct frame is powered up.  Verify that all appropriate rear connections are secure.  Gently push the module into its slot in the frame to ensure it is seated properly. Then ...
  • Page 38: Index

    Index Symbols – – 1X8 Work mode 11 Jumper setting 5 – 2X4 work mode 10 6800+ETH module 7 – LEDs 18 – Local/Remote jumper 5 – AES x Alarm Switch Level 13 Alarms 19 – Audio configuration 10 – Monitoring and module status LEDs 18 Back module 3 Operating notes 7...