Siemens SITRANS F M MAG 3100 Operating Instructions Manual page 52

Electromagnetic flowmeters
Hide thumbs Also See for SITRANS F M MAG 3100:
Table of Contents

Advertisement

Technical data
Table 8- 5
Media temperature
Version
PTFE Teflon
PFA
Neoprene
EPDM
Linatex®
Ebonite
Table 8- 6
Design
Version
Weight
Flange and housing material
Measuring pipe material
Electrode material
50
MAG 3100 P
-20 ... +130 °C (-4 ... +266
°F)
-20 ... +150 °C
(-4 ... +300 ºF)
MAG 3100 P
See dimensional drawings
Carbon steel ASTM A
105, with corrosion
resistant two component
epoxy coating (min. 150
μm)
AISI 304 (1.4301)
Hastelloy C276 (PFA:
Hastelloy C22
MAG 3100
-20 ... +100 °C (-4 ... +212
°F)
-20 ... +100 °C
(-4 ... +212°F)
0 ... +70 °C (32 ... 158 °F)
-10 ... +70 °C (14 ... 158 °F)
-40 ... +70 °C (-40 ... +158
°F)
For temperatures below -20
°C (-4 °F) AISI 304 or 316
flanges must be used
0 ... 95 °C (32 ... 203 °F)
MAG 3100
Carbon steel ASTM A
105, with corrosion
resistant two component
epoxy coating (min. 150
μm)
AISI 304 (1.4301) flanges
and carbon steel
housing, with corrosion
resistant two component
epoxy coating (min. 150
μm)
AISI 316 L (1.4404)
flanges and housing,
polished
AISI 316 Ti (1.4571)
Hastelloy C276 (PFA:
Hastelloy C22)
Platinum/Iridium,
Titanium
Tantalum
Operating Instructions, 06/2010, A5E03005599-01
MAG 3100 HT
-20 ... +130 °C (-4 ...
+266 °F)
-20 ... +180 °C (-4 ...
+356 °F)
Factory mounted grounding
rings type E and SS terminal
box. Can only be used with
remote transmitter.
-20 ... +150 °C
(-4 ... +300 °F)
MAG 3100 HT
Carbon steel ASTM A
105, with corrosion
resistant two component
epoxy coating (min. 150
μm)
AISI 304 (1.4301) flanges
and carbon steel
housing, with corrosion
resistant two component
epoxy coating (min. 150
μm)
AISI 316 L (1.4404)
flanges and housing,
polished
AISI 316 Ti (1.4571)
Hastelloy C276 (PFA:
Hastelloy C22)
Platinum/Iridium,
Titanium
Tantalum
SITRANS F M MAG 3100

Hide quick links:

Advertisement

Table of Contents
loading