Installing/Mounting

4.3 Orienting the sensor

Example:
A flow of 3 m/s (V) in a sensor with a diameter reduction from DN 100 to DN 80 (d
gives a pressure drop of 2.9 mbar.
For installation conditions for transmitters, see respective transmitter operating instructions.
4.3
Orienting the sensor
The sensor operates in all orientations, but Siemens has the following recommendations:
● Vertical installation with an upwards flow
Figure 4-3
24
Vertical orientation, upwards flow
SITRANS F M MAG 3100
Operating Instructions, 06/2010, A5E03005599-01