Venting System Assemlby - Direct Vent
General Information
The Stardance is approved for installation only with the
vent components listed on Pages 13 & 14. Follow the
vent component instructions exactly.
For U.S. installations: The venting system must con-
form with local codes and/or the current National Fuel
Gas Code, ANSI Z3.1/NFPA 54.
For Canadian installations: The venting system must
conform to the current CSA B149.1 installation code.
Install the Vent Adapter Pipe
(MHSC Vent Components)
1. Attach Inner Starter Pipe, (found in the parts
bag), to the next section of inner pipe.
• Run a bead of sealant about 1/" from the upper
end of the Inner starter pipe and join the two sections
together.
• Drill three pilot holes into the Inner Starter and
secure the assembly with three sheet metal screws.
(Fig. 18)
3" Inner
Starter PIpe
Fig. 18 Connect the inner starter with the next section of in-
ner vent pipe.
2. Dry fit the Inner Pipe assembly to the stove for
the purpose of determining the center line of the
pipe on the wall.
• Side Wall Terminations: Dry fit the outer elbow
with the vertical outer vent and confirm the centerline
ST211
alignment with the wall thimble opening.
attach inner pipe
3. Attach the Inner Vent Assembly to the stove.
to next section
• Run a bead of sealant around the bottom end of
12/4/99 djt
the starter pipe and attach the assembly to the stove
using three 1/4-0 x 3/8" Phillips screws provided in
the parts bag. (Fig. 19)
4. Install the Outer Adapter Pipe. Apply a 1/4" bead
of cement around the inside wall of the pipe, about
1" from the end. Insert the pipe over the stove flue
collar, keeping the vertical seam oriented to the back
of the stove. Also, be sure to align holes on the pipe
with the holes on the flue collar of the firebox. Fasten
the pipe to the holes in the flue collar with the #1 x
1/" sheet metal screws provided. (Fig. 0)
16
First Section of Vent
Pipe
#8 x 1/" Sheet
Metal Screws
ST11
Fig. 19 Attach inner assembly to flue collar.
ST212a
attach inner assy
no restrictor plate
6/07 djt
Fig. 20 Fasten outer pipe with #1 x 1/" sheet metal screw.
Install the Vent Adapter Pipe
(Simpson Dura-Vent Components)
ST213
1. Discard the inner starter pipe shipped with the
install outer adpater
stove. Using the starter pipe assembly listed on
Page 7, slide the inner section out to allow access.
12/6/99 djt
• Run a bead of sealant around the bottom end of
the starter pipe and attach the assembly to the stove
using three 1/4-0 x 3/8" Phillips screws provided in
the parts bag. (Fig. 1)
2. Install the Outer Adapter Pipe. Apply a 1/4" bead of
cement around the outside surface, about one inch
from the crimped end. (Fig. ) Orient the vertical
seam to the rear, and insert the crimped end of the
outer pipe into the flue collar. Fasten with three sheet
metal screws provided.
ST1a