ISO Parameters
Tab. 10-9 Description of ISO Parameters
Parameter
Description
Set the ISO protection function to ON
or OFF. When it is ON, inverter will not
ISO
connect to the grid when resistance
to the ground is below the set value.
ISO
pro
Set the resistance to the ground.
value
10.7.4

Protection Parameters

Click the "Protection parameter" to check the protection parameter and set the
related parameters as shown in Fig. 10-27.
User can only check the parameter in this interface. The default values of the
protection parameters have been preset as per grid code of corresponding
countries.
To set the protection parameter, please contact Sungrow to acquire advanced
password.
Fig. 10-26 ISO Parameters
10 Sun Access APP
Default
Range
[ON]
[OFF]/ [ON]
50KΩ
20~3000KΩ
74