PID control parameter
Parameter
PID
Recovery(Night)
Anti-PID(Day)
PID alarm clearing
After the PID Recovery(Night) / Anti-PID(Day) function is enabled,
the fault indicator on the inverter main panel turns green.
The PID night recovery function and the PID day protection
function cannot be enabled at the same time.
10.8.5 Protection Parameters
Click the "
related parameters as shown in the following figure.
User can only check the parameter in this interface. The default
values of the protection parameters have been preset as per grid
code of corresponding countries.
To set the protection parameter, please contact SUNGROW to
acquire advanced password.
Fig. 10-17 PID control parameters
Description
Set enabling/disabling of the PID night recovery
function. PID night recovery functions between 22:00
pm and 5:00 am by default.
Set enabling/disabling of the PID day protection
function. PID day protection functions only when the
inverter is in grid-connected state.
If ISO impedance abnormality or PID function
exception is detected during running of the PID
function, the inverter reports a PID false alarm and
reminds the user to take corresponding measures.
After processing, the alarm information can be cleared
via the function.
" to check the protection parameter and set the