Panasonic KX-TDA30 Installation Manual page 160

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA30:
Table of Contents

Advertisement

4.1 Troubleshooting
PROBLEM
Cannot register the PS.
PS becomes out of
range.
Cannot make calls using
the PS.
Noise is frequent while
using the PS.
Conversations
disconnect while using
the PS.
PS stays out of service
when the CS status is
changed from Out of
Service to In Service.
160
Installation Manual
PROBABLE CAUSE
Wrong Personal
Identification Number
(PIN) is registered to the
PS.
CS is not connected
properly.
CS is not working.
Location of CS is not
good.
Access system of the
PS is not properly set.
Call handover is not
working.
PS is out of CS coverage
area.
It may take about 20 s
for CS to start up after
the status has been
changed to In Service.
SOLUTION
Register the PIN set to the Hybrid IP-
PBX into the PS.
Make sure that the cable is connected
properly with correct pin assignments.
Also, make sure that the cable does not
make short circuits.
Switch all DIP switches off.
Make sure that the cable is connected
properly with correct pin assignments.
Also, make sure that the cable does not
make short circuits.
Switch all DIP switches off.
Locate the CS properly (refer to "2.7.5
Site Survey Using the KX-TD7590" or
"2.8.5 Site Survey" ).
Change the access system setting of
the PS to the appropriate system or
automatic.
Locate the CS properly (refer to "2.7.5
Site Survey Using the KX-TD7590" or
"2.8.5 Site Survey" ).
Wait until the CS starts up.

Hide quick links:

Advertisement

Table of Contents