Pow-R-Command 2000 General Overview - Emerson E2 Installation And Operation Manual

Eaton breaker panel
Hide thumbs Also See for E2:
Table of Contents

Advertisement

Pow-R-Command 2000 General Overview

In businesses of all types, there are numerous variables that signifi-
cantly influence profitability. Among these variables are: electrical
consumption, construction time and the ease with which employees
use the facility. Eaton's Cutler-Hammer Pow-R-Command 2000
system can have a positive impact on all of these elements.
Energy Costs
Among the various factors that contribute to total energy costs are:
the times that energy is used and the amount of energy used at any
point in time. The Pow-R-Command 2000 can help control both of
these. With integral time control and the ability to stagger the start
time of groups of devices, the Pow-R-Command 2000 system can
help a facility manage its electrical consumption. Furthermore, a
Pow-R-Command 2000 system can be integrated with a metering
system to monitor and control electrical use.
Reduced Construction Time and Space
In each Pow-R-Command 2000 panelboard are revolutionary devices
known as Smart Breakers. Eaton's Smart Breaker combines the inter-
rupting ability of a standard branch circuit breaker with a remote
switching ability. Smart Breakers mount in any standard Cutler-
Hammer brand panelboard, and can be intermingled with standard
branch circuit breakers. Because no additional structures are needed
to mount the Smart Breaker, the extra material and labor from the
contactor or relay cabinets are eliminated.
Lighting Control With No Additional Structures
The Pow-R-Command 2000 controller and associated Smart Breakers
mount directly into a standard Cutler-Hammer brand panelboard.
Such panelboards would be required in a facility even if no lighting
control is installed. As a result of this, the Pow-R-Command 2000
system and all of its abilities can be installed in the same structures
that would normally be required.
Lighting Control With No Additional Labor
When using contactors or relays to control lighting, there are four
basic elements that need to be integrated into a circuit. This includes
a standard branch circuit breaker mounted in a panelboard, a relay or
contactor mounted in a separate cabinet, a controller mounted in a
cabinet, and the lighting loads. On the job site, the contractor would
need to install pipe and wire from the controller and branch circuit
breaker to the contactor or relay and then to the lighting load. Since
the controller, branch device and remote controlled switching device
are all located in one Pow-R-Command 2000 structure, the contractor
only needs to pipe and wire from the Pow-R-Command 2000 panel-
board to the lighting load.
Product Support and Technical Assistance
Eaton has 17 locations that are fully capable of manufacturing and
supporting the Pow-R-Command 2000 product. Technical and
application engineering services are available by calling 1-888-252-
6286. In addition to technical support, field study and coordination
of electrical and lighting control systems is available through Eaton
Engineering Services.
Proof #4 — Zoltun Design — January 26, 2009
EATON CORPORATION Cutler-Hammer Pow-R-Command 2000 System Overview Technical Data TD01412050E
Copyright 2009
©
3