Installation Information
Dual Unit Installations
If two or more units are placed side by side and are
2" or less apart, a dual unit heater package must be
applied to the left side of the right hand unit.
Failure to install the dual unit heater package could
result in exterior condensation between the units.
If two Tall units are installed side by side and are 2"
or less apart, part #TTDUAL should be utilized.
(See Figure 2-6)
If two Base units are installed side by side and are
2" or less apart, part #BBDUAL should be utilized
If a Tall unit is installed next to a Base unit and they
are 2" or less apart, part #BBDUAL should be uti-
lized.
Complete installation instructions are supplied with the
#BBDUAL and #TTDUAL packages.
#3758412 - Revision B - December, 2006
Integrated
Integrated
(700-
(700-
Apply heater
to left side of
right hand
unit
Figure 2-6. Dual Unit Heater (#TTDUAL Shown)