Error Code Table; Clearing Error Codes - Sub-Zero 700TC-3 Service Manual

Integrated 700-3 tall series
Table of Contents

Advertisement

Integrated
Integrated
CODE INDICATION
05
Refrig. cabinet thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp's
06
Refrig. evaporator thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp's
07
Freezer cabinet thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp's
08
Freezer evaporator thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp's
20
Defrost under-heat with no voltage feedback through Gray/White wire at defrost start
21
Defrost overheat
22
No voltage feedback through Gray/White wire at defrost start
23
Defrost overheat with no voltage feedback through Gray/White wire at defrost start
24
Defrost Under-heat
30
Excessive Icemaker Water Valve Solenoid Activation (Exceeded 15 Seconds)
40
Excessive Freezer Compressor Run
50
Excessive Refrigerator Compressor Run
NOTE: The table above will be updated through addendums when subsequent software and electrical changes
occur and more error codes are added.

Clearing Error Codes

If error codes are observed during Diagnostic Mode, a non-flashing SERVICE annunciator will appear on the LCD
when Diagnostic Mode ends, indicating error codes are still registered (See Figure 3-56). To clear a non-flashing
SERVICE annunciator and the error codes, the problem must be corrected and the unit must be ON. Then, the Bell
ON/OFF key must be pressed and held for fifteen (15) seconds. The control will emit a short "beep" when the SER-
VICE annunciator and error codes are cleared. (See Figure 3-57)
SERVICE
Figure 3-56. Non-flashing SERVICE Annunciator after Diagnostic Mode = Error Codes were Registered
Figure 3-57. Clear Non-flashing SERVICE Annunciator - Press & Hold Bell ON/OFF Key for 15 Seconds
3
3
(700-
T
ALL)
(700-
T
ALL)

Error Code Table

B B E E E E P P ! !
Series
Series
FREEZER
COLDER
WARMER
COLDER
FREEZER
COLDER
WARMER
COLDER
Press and hold for 15 seconds
3-23
Electronic Control System
ICE
REFRIGERATOR
WARMER
ON/OFF
ICE
REFRIGERATOR
WARMER
ON/OFF
#3758412 - Revision B - December, 2006
UNIT
ON/OFF
ON/OFF
UNIT
ON/OFF
ON/OFF

Advertisement

Table of Contents
loading

Table of Contents