Sub-Zero 700TC-3 Service Manual page 98

Integrated 700-3 tall series
Table of Contents

Advertisement

Troubleshooting Guides
ERROR CODE TROUBLESHOOTING GUIDE
ERROR CODE
30
A. Check for jammed cube in icemaker.
B. Reference wiring diagram to identify components in same White wire circuit as water valve solenoid.
40
A. If Error Code 07, 20, 21, 22, 23, or 24 is also displayed during Diagnostic Mode, see Test/Actions
B. Check for obstructions to freezer door/drawer closing. Remove obstruction.
C. Check cleanliness of condenser. Clean if needed.
D. Check for obstruction to condenser fan blade or loose fan blade. Remove obstruction/Tighten Blade.
E. Check evaporator fan blade position and for obstructions. Reposition if incorrect/Remove obstruction.
F.
G. With unit on, check to see if lights shut off when light switch is depressed. Repair defective wiring or
H. With freezer compressor running:
I.
J.
50
A. If Error Code 05, or 06 is also displayed during Diagnostic Mode, see Test/Actions under that code.
B. Check for obstructions to refrigerator door closing. Remove obstruction.
C. Check cleanliness of condenser. Clean if needed.
D. Check for obstruction to condenser fan blade or loose fan blade. Remove obstruction/Tighten Blade.
E. Check evaporator fan blade position and for obstructions. Reposition if incorrect/Remove obstruction.
F.
G. With unit on, check to see if lights shut off when light switch is depressed. Repair defective wiring or
H. With refrigerator compressor running (All models except 700TF/I) check for 115 V AC from control
I.
J.
NOTE: After repairs, always clear Error Codes by pressing Bell ON/OFF key for 15 seconds.
#3758412 - Revision B - December, 2006
Check all White wire electrical connections and continuity from water valve solenoid to J7-8 on control
board.
under that code.
Check resistance of freezer compartment thermistor - 30,000 to 33,000 ohms at 32°F (0°C). Replace
if defective.
replace defective switch.
1.
(Model 700TF/I Only) Check for 115 V AC from compressor to condenser fan. Repair defective
wiring or replace defective motor.
2.
(All Models Except 700TF/I) Check for 115 V AC from control board to condenser fan. Repair
defective wiring, or replace defective motor, or replace defective board.
With freezer compressor running and fan switches depressed, check for 115 V AC from compressor to
evaporator fan motor. Repair wiring, or replace defective switch, or replace defective fan motor.
Check sealed system for leaks, restrictions or inefficient compressor.
Check resistance of refrigerator compartment thermistor - 30,000 to 33,000 ohms at 32°F (0°C).
Replace if defective.
replace defective switch.
board to condenser fan. Repair defective wiring, or replace defective motor, or replace defective
board.
With refrigerator compressor running and fan switches depressed (All Models Except 700TF/I), check
for 115 V AC from compressor to evaporator fan motor. Repair wiring, or replace defective switch, or
replace defective fan motor.
Check sealed system for leaks, restrictions or inefficient compressor.