Level II program parameters can be adjusted to fine-tune
the conditioner's operation. The parameters are
accessible by pressing and holding the UP and DOWN
buttons until the control displays a "P" value. Note: The
control must be in the home position to change settings.
See Table below for Level ll parameters. Typically the Level
Description
P9
Units of Measure
P10
Clock Mode
P11
Service Interval
Remote
P12
regeneration
switch delay
Chlorine Generator
Options
P13*
(not used on
Magnum systems)
P14* Refill Rate
P15* Draw Rate
Reserve Type
P16
(not used for
alternating mode)
Initial average or
fixed reserve
P17
(not used for
alternating mode)
P18
Flow sensor select
K-factor or Pulse
P19
equivalent
Notes: (1) Default selected with valve type and resin volume.
(2) Factory Default is "0" for North America units and "1" for World units.
*Not used for Magnum valves.
Minimum
Range
Increments
0-1
1
0-1
1
0-250
1
3-250
1
0-2
1
1-700
1
1-700
1
0-3
1
0-70
1
0-5
1
1.00-
0.01
99.99
1
0-9999
ll parameters will not need to be adjusted as the default
settings accommodate most applications. Contact your
Water Treatment Professional before attempting any
programming.
Default
Units
(2)
0 = US 1 = Metric
(2)
0 = 12 Hr 1 = 24 Hr
0
Months
Uses 30 days for each month; 0 = off
Time remote switch must be active
60
seconds
to start regeneration.
0 = No chlorine generator
0
1 = salt check only
2 = generate chlorine
(1)
gpm x 100
(1)
gpm x 100
0 = variable reserve delayed
regeneration
1 = fixed reserve delayed
regeneration
0
2 = variable reserve immediate
regeneration
3 = fixed reserve immediate
regeneration
% of
30
Depends on value entered in P16
Capacity
0 = internal magnum NHWB,
1=1" turbine
2 = 2" turbine
(1)
3 = User defined K-factor
4 = User defined pulse equivalent
5 = Internal Magnum HWB
0.01
K-factor P18=3;
1
Pulse Equivalent P18 = 4
33
Notes