Troubleshooting; 764 Controller - Error Codes & 298 "L" With Check Salt Light - GE Logix 764 Operation Manual

With 293 magnum it; 298 magnum it twin alternating; twin parallel; single with remote regeneration start; multi-single tank with lockout
Table of Contents

Advertisement

Troubleshooting

764 Controller – Error Codes & 298 "L" with Check Salt Light
Problem
ERR 1 is displayed.
ERR 3 is displayed.
Possible Cause
Program settings have been corrupted.
Controller on tank 1 does not know the
position of the camshaft. Camshaft
should be rotating to find Home position.
Camshaft on tank 1 is not turning during
ERR 3 display.
Camshaft on tank 1 is turning more than
five minutes to find Home position:
Regeneration starts but control shows
Err3 before completing regeneration.
41
Solution
Press any key and reprogram Level I
settings.
Wait for two minutes for the controller to
return to Home position. The hourglass
should be flashing on the display
indicating the motor is running.
Check that motor is connected. Verify that
motor wire harness is connected to motor
and controller module.
Verify that optical sensor is connected
and in place.
Verify that motor gear has engaged cam
gear.
If everything is connected, try replacing in
this order:
1. Wire Harness, Motor, Optical Sensor
Assy
2. Controller
Verify that optical sensor is in place and
connected to wire.
Verify that camshaft is connected
appropriately.
Verify that no dirt or rubbish is clogging
any of the cam slots.
If motor continues to rotate indefinitely,
replace the following components in this
order:
1. Wire Harness, Motor, Optical Sensor
Assy
2. Controller
Verify that the correct valve is selected in
the Logix controller.