Connection Terminals/Functions - Banner MMD-TA-11B Instruction Manual

Muting module
Table of Contents

Advertisement

System Installation
3.4 Connection Terminals and Functions
All electrical connections are made through removable terminals
(see Figures 3-4a and 3-4b).
To disable the SSI, terminal X5 (SSIb) must be jumpered to
terminal X6 (SSIa), and terminal X7 (SSId) must be jumpered to
terminal X8 (SSIc) (factory default). Do not short Channel A to
Channel B.
All terminals are low-voltage,
except for those indicated
otherwise
Z13 M3 Z23
Z21 M1 Z11
Z12 M2 Z22
S11 S12 S21 S22
X5 X6
X7 X8
X9 X10 X11 X12
Y1 Y2 Y3
Y4
X3
X4
31
32
13
14
A1
X1 X2
Z14 M4 Z24
X13 X14 A2
Potential
High-Voltage
Terminals
Figure 3-4a. MMD-TA-11B terminal connection locations
All terminals are low-voltage
Z13 M3 Z23
Z21 M1 Z11
Z12 M2 Z22
X9 X10 X11 X12
S11 S12 S21 S22
X5
X6
X7
X8
Y1
Y2
Y3
Y4
X3
X4
Z3
Z4
Y5
Y6
A1
X1 X2
Z14 M4 Z24
X13 X14 A2
Figure 3-4b. MMD-TA-12B terminal connection locations
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Terminal
Function
Z13
M3, 0V
M3
Muting 3 In (PNP)
Z23
M3, 24V
S11
MSSI b (ch A)
S12
MSSI a (ch A)
S21
MSSI d (ch B)
S22
MSSI c (ch B)
Y1
EDM 1 a Out (24V)
Y2
EDM 1 b In
Y3
EDM 2 b In
23
24
Y4
EDM 2 a Out (24V)
A1
+24V dc
X1
Reset In
X2
Reset Out (24V)
Terminal
Function
Z13
M3, 0V
M3
Muting 3 In (PNP)
Z23
M3, 24V
S11
MSSI b (ch A)
S12
MSSI a (ch A)
S21
MSSI d (ch B)
S22
MSSI c (ch B)
Y1
EDM 1 a Out (24V)
Y2
EDM 1 b In
Y3
EDM 2 b In
Y7
Y8
Y4
EDM 2 a Out (24V)
A1
+24V dc
X1
Reset In
X2
Reset Out (24V)
MMD-TA-11B / MMD-TA-12B Muting Module
WARNING . . .
Hookup
Electrical hookup must be made by Qualified
Personnel and must comply with NEC (National Electrical
Code) and local standards.
Make no connections to the System other than those
described in Section 3 of this manual. Doing so could result
in serious injury or death.
Terminal
Function
Z21
M1, 24V
M1
Muting 1 In (PNP)
Z11
M1, 0V
X5
SSI b (ch A)
X6
SSI a (ch A)
X7
SSI d (ch B)
X8
SSI c (ch B)
X3
Mute Lamp Out (24V)
X4
Mute Lamp In
31
AUX a (Relay)
32
AUX b (Relay)
Z14
M4, 0V
M4
Muting 4 In (NPN)
Z24
M4, 24V
Terminal
Function
Z21
M1, 24V
M1
Muting 1 In (PNP)
Z11
M1, 0V
X5
SSI b (ch A)
X6
SSI a (ch A)
X7
SSI d (ch B)
X8
SSI c (ch B)
X3
Mute Lamp Out (24V)
X4
Mute Lamp In
Z3
AUX b 0V
Z4
AUX a Out
Z14
M4, 0V
M4
Muting 4 In (NPN)
Z24
M4, 24V
Instruction Manual
Proper Electrical
Terminal
Function
Z12
M2, 0V
M2
Muting 2 In (NPN)
Z22
M2, 24V
X9
Override a (ch A)*
X10
Override b (ch A)*
X11
Override c (ch B)*
X12
Override d (ch B)*
13
OSSD 1 a (Relay)
14
OSSD 1 b (Relay)
23
OSSD 2 a (Relay)
24
OSSD 2 b (Relay)
X13
Mute Enable Out (24V)
X14
Mute Enable In
A2
0V dc
*contacts only
Terminal
Function
Z12
M2, 0V
M2
Muting 2 In (NPN)
Z22
M2, 24V
X9
Override a (ch A)*
X10
Override b (ch A)*
X11
Override c (ch B)*
X12
Override d (ch B)*
Y5
OSSD 1 a Out
Y6
OSSD 1 b 0V
Y7
OSSD 2 b 0V
Y8
OSSD 2 a Out
X13
Mute Enable Out (24V)
X14
Mute Enable In
A2
0V dc
*contacts only

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mmd-ta-12b

Table of Contents