6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Indoor Unit
Parts name
No.
1
Fan motor (for indoor)
2
Room temp. sensor (TA-sensor)
3
Heat exchanger temp. sensor (TC-sensor)
Heat exchanger temp. sensor ( TCJ-sensor )
4
5
Louver motor
6-2. Outdoor Unit
No.
Parts name
1
Reactor
2
Outdoor fan motor
3
Suction temp. sensor (TS sensor)
4
Discharge temp. sensor (TD sensor)
5
Outside air temp. sensor (TO sensor)
6
Heat exchanger temp. sensor (TE sensor)
7
Terminal block (6P)
RAS-25PAVPG-ND
8
Compressor
RAS-35PAVPG-ND
9
Coil for PMV
10
Coil for 4-way valve
Type
ICF-340U30-2
DC340, 30W
( - )
10k
(
)
10kΩ at 25°C
-
(
)
10kΩ at 25°C
-
MP24Z4N
Output (Rated) 1W, 16 poles, DC12V
Mode l na me
CH-57-WL
L = 9.45mH, 16A
ICF-340-A70-1
DC140V, 70W
(Inverter attached)
10kΩ (25°C)
(Inverter attached)
62kΩ (20°C)
(Inverter attached)
10kΩ (25°C)
(Inverter attached)
10kΩ (25°C)
JX0-6B
20A, AC250V
3-phases 6-poles 1075W
KTN130D30UFZ
KTN150D42UFZ
3-phases 6-poles 1185W
CAM-MD12TCTH-5
DC12V
STF-H01AJ
AC Type
- 19 -
FILE NO. SVM-17050
Specif icat io ns
at 25°C
Rating