10-5-2. Power Supply and Connecting Cable Connection
Power supply cable
Cord clamp
Screw
Connecting CABLE
Power supply terminal block (L, N, ˙)
Plastic wire guide
Stripping length of the connecting cable
Earth line
50 mm
Connecting cable
10 mm
3
45 mm
Connecting CABLE
Connecting cable connect
to terminal block (L, N)
Stripping length of the connecting cable
Earth line
50 mm
10 mm
3
10 mm
45 mm
N
L
90 mm
10 mm
Power Supply Input at Indoor Unit Terminal Block (Recommend)
Indoor Unit
Stripping length of the
power supply cable
100 mm
10 mm
N
L
10 mm
Connecting terminal block
(1, 2, 3, ˙)
Earth line
Connecting cable cord
Power supply cord
Power Supply Input at Outdoor Unit Terminal Block (Optional)
Indoor Unit
Connecting cable connect
to terminal block (3, ˙)
Connecting cable
Earth line
Terminal block
90 mm
Connecting cable
connect to terminal
block (1, 2, 3, ˙)
Terminal block
1 2 3
30
Connecting cable
- 77 -
FILE NO. SVM-17050
Outdoor Unit
Connecting cable connect to
terminal block (1, 2, 3, ˙)
1
2
3
L
N
Connecting cable
1 2 3
40
30
Earth line
Connecting cable
Outdoor Unit
Power supply
terminal block
(L, N, ˙)
1
2
3
L
N
Connecting
Power cord
cable
L N
40
40
30
Earth line
Earth line
Power cord