Toshiba RAS-25PAVPG-ND Service Manual page 21

Split-type
Hide thumbs Also See for RAS-25PAVPG-ND:
Table of Contents

Advertisement

RAS-35PKVPG-ND / RAS-35PAVPG-ND
Pressure measurement
P
Gauge attaching port
Vacuum pump connecting port
Deoxidized copper pipe
Outer dia. : 9.52mm (35)
: 12.7mm (45)
Thickness : 0.8mm
4-way valve
TS
Temp. measurement
NOTE :
• The maximum pipe length of this air conditioner is 25 m. When the pipe length exceeds 15m, the additional
charging of refrigerant, 20g per 1m for the part of pipe exceeded 15m is required. (Max. 200g)
INDOOR UNIT
Indoor heat
exchanger
Cross flow fan
Deoxidized copper pipe
Outer dia. : 6.35mm
Thickness : 0.8mm
Sectional shape
of heat insulator
Muffler
Muffler
TD
Compressor
KTN150D42UFZ
Outdoor heat
exchanger
T2
Propeller fan
OUTDOOR UNIT
- 21 -
Temp. measurement
T1
Tcj
TC
TA
Strainer
TO
Split capillary
Ø1.0 x 80
Ø1.0 x 80
TE
NOTE :
FILE NO. SVM-17050
Max.
: 25m
Min.
: 2m
Chargeless : 15m
Charge : 20g/m
(16 to 25m)
Dryer
Pulse Modulating
valve at liquid side
Refrigerant amount : 1.05kg
Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-25pkvpg-ndRas-35pkvpg-ndRas-35pavpg-nd

Table of Contents