9-3-2. How to Set the Auto Restart Function
To set Auto Restart Function, proceed as follows:
1. The power supply to the unit must be ON ; The function will not set or reset if the power supply is OFF.
2. Press the [RESET] button located on the front panel of the indoor unit for more than 3 seconds.
3. After 3 seconds, the unit beeps three times and the indicator blinks for 5 seconds.
• When the unit is standby (Not operating)
Operation
Press [RESET] button for more than
three seconds. (Less than 10 seconds)
Temporary switch
• When the unit is in operation
Operation
Press [RESET] button for more than
three seconds. (Less than 10 seconds)
Temporary switch
• While the filter check indicator is on, the RESET button has the function of filter reset betton.

9-3-3. Power Failure During Timer Operation

• If Timer operation is set and the power supply shut down accidentally, the previous Timer setting
will be cancelled.
• Weekly-timer operation will be not affected by power supply failure, if the remote controller is
located on the position which it can send the command signal to the indoor unit. It is because the remote
controller will send signal when real clock reach to program setting.
The unit is on standby.
The unit starts to operate.
After approx. three seconds,
The unit beeps three times
and continues to operate.
If the unit is not required to operate at this time, press [RESET]
button once more or use the remote controller to turn it off.
The unit is in operation.
The unit stops operating.
After approx. three seconds,
The unit beeps three times.
If the unit is required to operate at this time, press [RESET] button
once more or use the remote controller to turn it on.
- 52 -
FILE NO. SVM-17050
Motions
The blue indicator is on.
The blue indicator flashes
for 5 seconds.
Motions
The blue indicator is on.
The blue indicator is turned off.
The blue indicator flashes
for 5 seconds.