MENU OPERATION - CONT'D
SERVICE MODE MINIMUM RATE
This feature will run the burner at
minimum rate. Note that a CH demand
has to already be present for this feature
to be active. To activate the feature press
MENU and the following screen will be
displayed.
MENU
SHOW EFFICIENCY LEVEL
SERVICE COMPANY NAME
SERVICE COMPANY PHONE NUMBER
SELECT
EXIT
Press
until the following screen is
displayed.
MENU
MAXIMUM FLOW TEMPERATURE
SERVICE MODE
PUMP MODULATION
PLOT GRAPHS
SELECT
EXIT
Press SELECT and the following screen
will be displayed.
SERVICE MODE
MINIMUM CH RATE
MAXIMUM CH RATE
SELECT
EXIT
Press SELECT and the following screen
will be displayed.
SERVICE MODE
MINIMUM CH RATE
FAN TARGET
18%
FAN ACTUAL
18%
TIME LEFT
15 min
EXIT
Operation will end automatically after 10
mins or press EXIT to end manually.
42
42
SECTION 2 - INSTALLATION
SERVICE MODE MAXIMUM RATE
This feature will run the burner at
maximum rate. Note that a heat demand
has to already be present for this feature
to be active. Gas rate will reduce as
flow temperature approaches 80ºC. To
activate the feature, press MENU and the
following screen will be displayed.
MENU
SHOW EFFICIENCY LEVEL
SERVICE COMPANY NAME
SERVICE COMPANY PHONE NUMBER
SELECT
Press
until the following screen is
displayed.
MENU
MAXIMUM FLOW TEMPERATURE
SERVICE MODE
PUMP MODULATION
PLOT GRAPHS
SELECT
Press SELECT and the following screen
will be displayed.
SERVICE MODE
MINIMUM CH RATE
MAXIMUM CH RATE
SELECT
Press
and the following screen will be
displayed.
SERVICE MODE
MINIMUM CH RATE
MAXIMUM CH RATE
SELECT
Press SELECT and the following screen
will be displayed.
SERVICE MODE
MAXIMUM CH RATE
FAN TARGET
FAN ACTUAL
TIME LEFT
Operation will end automatically after 10
mins or press EXIT to end manually.
PUMP MODULATION
The boiler is factory set for pump
modulation to occur. If you wish to
disable modulaton, press MENU and the
following screen be displayed.
SHOW EFFICIENCY LEVEL
SERVICE COMPANY NAME
SERVICE COMPANY PHONE NUMBER
Press
EXIT
displayed.
PUMP MODULATION
3 WAY VALVE MIDPOSITION
Press SELECT and the following screen
EXIT
will be displayed.
PUMP MODULATION
70% is equivalent to 6m head of pressure
100% is equivalent to 7m head of pressure
SERVICE COMPANY PHONE NUMBER
Press
EXIT
press SET to enable.
EXIT
73%
73%
15 min
EXIT
MENU
SELECT
EXIT
until the following screen is
MENU
SERVICE MODE
PLOT GRAPHS
SELECT
EXIT
MENU
SHOW EFFICIENCY LEVEL
HOT WATER PREHEAT ON / OFF
SET
EXIT
SERVICE COMPANY NAME
or
to change the setting and
SELECT
EXIT