SECTION 2 - INSTALLATION

2.21 EXTERNAL ELECTRICAL CONTROLS

Wiring External to the Boiler
The fuse rating should be 3A.
EXAMPLE - Connection to Honeywell Evohome
Wiring external to the boiler MUST be in
accordance with the current I.E.E. (BS 7671)
Wiring Regulations and any local regulations.
Frost Protection
If parts of the pipework run outside the house or if
the boiler will be left off for more than a day or so
then a frost thermostat should be wired into the
system.
The frost thermostat should be sited in a cold
place but where it can sense heat from the
system.
Note. If the boiler is installed in a garage it may
be necessary to fit a pipe thermostat, preferably
on the return pipework.
(for additional information visit www.honeywelluk.com)
33