When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal.
Important Notes Natural Gas only Destination Countries: GB, IE • This appliance must not be operated without the casing correctly fitted. • Do not store objects around or on the boiler, and keep access clear at all times. • Do not obstruct ventilation ducts, grilles or openings in the boiler room, room space or compartment that the appliance is installed in, or the passage of combustion and ventilation to the boiler.
Page 3
BOILER CONTROLS / DISPLAY (MASTER PANEL SHOWN) EVOMOD USER INTERFACE Ideal Mains On When the mains to the boiler is switched on a screen similar to the following will be displayed. Initialising Please Wait U/I PCB 330.E18 Pri’ PCB 332.E08...
Page 4
SETTING FLOW TEMPERATURE Press SELECT and a screen similar to the following will be displayed The kW output number in the 1st line will vary depending on the maximum output of the boiler Ideal 750kW Normal Operation Set Flow Temp’ Set Off/On...
To shut Down the Boiler Condensate Drain 1. For short periods The condensate drain must not be modified or blocked. Set the external controls to OFF. Wait 2 minutes and then Blockage of the condensate drain, caused by debris or freezing, isolate the mains supply to the boiler.
Page 6
Ideal Boilers Ltd. pursues a policy of continuing improvement in the design and performance of its products. The right is therefore reserved to vary specification without notice. Ideal is a trademark of Ideal Boilers. Registered Office Ideal Boilers Ltd., PO Box 103, National Avenue, Kingston Upon Hull, HU5 4JN...
Need help?
Do you have a question about the EVOMOD 250 and is the answer not in the manual?
Questions and answers