IDEAL Vogue System Gen 2 S15 Installation And Servicing page 21

Table of Contents

Advertisement

DETERMINING THE FLUE LENGTH AND FLUE PACKS REQUIRED, CONT'D
FIGURE 1
Note. Maximum permissible
flue length is measured from
centre line of appliance flue
outlet to outside wall face.
FIGURE 2
Actual maximum flue length requirements
(outside edge of turret to out side face of wall plus 44mm (Cut Length))
Horizontal Flue Terminal
Minimum
B Pack (Standard)
Plus 1 (1m D pack)
Plus 2 (1m D pack)
Plus 3 (1m D pack)
Plus 4 (1m D pack)
Plus 5 (1m D pack)
Plus 6 (1m D pack)
Plus 7 (1m D pack)
Plus 8 (1m D pack)
Plus 9 (1m D pack)
Plus 10 (1m D pack)
Note; Telescopic flue B Pack or attached "D" pack extensions do not need to be cut between minimum and maximum values
shown above (except where specified). Horizontal Flue Terminal (600mm long) B Pack flue will require cutting on values
below maximum values shown above.
Installation and Servicing
SECTION 2 - INSTALLATION
Edge of turret
to outside face of wall plus
44mm = ue length
A
100mm
REAR
Fit
to wall
NOTES
Centre of turret to edge of turret = 100mm
Turret has a ue insertion of 30mm
The distance from the outer wall face to the wall seal ue mounting point is 14mm
Wall Mounted template & Flue
Minimum & Maximum finished flue lengths obtainable (dimension 'A' +44mm)
Telescopic Flue B Pack
(600mm long) B Pack
Maximum
Minimum
233
602
340
1183
1552
1290
2133
2502
2240
3083
3452
3190
4033
4402
4140
4983
5352
5090
5933
6302
6040
6883
7252
6990
7833
8202
7940
8783
9152
8890
9733
N/A
9840
Edge of turret
to outside face of wall plus
44mm = ue length
A
REAR
Fit
to wall
inc. Stand
o Frame
Flue length measured from outer terminal lip
Horizontal Flue
Terminal (1000mm long)
B Pack (Telescopic)
Maximum
Minimum
Maximum
553
652
1503
1602
1819
2453
2552
2769
3403
3502
3719
4353
4452
4669
5303
5402
5619
6253
6352
6569
7203
7302
7519
8153
8252
8469
9103
9202
9419
10000
N/A
Edge of turret
to outside face of wall plus
44mm = ue length
A
SIDE
Fit
to wall
Minimum clearance 2.5mm
to end of outer ue
A + 44mm
Horizontal Flue Terminal
(1000mm long) B Pack
(Telescopic) Cut 75mm
Minimum
Maximum
869
577
794
1527
1744
2477
2694
3427
3644
4377
4594
5327
5544
6277
6494
7227
7444
8177
8394
9127
9344
N/A
N/A
N/A