6.18.4 Acceleration / Deceleration

DRIVECOM
Acceleration
Deceleration
Parameter description
Acc delta speed [FF]
Acc delta time [s]
Dec delta speed [FF]
Dec delta time [s]
QStp delta speed [FF]
QStp delta time [s]
Quick stop
Quick stop (0)
No Quick stop (1)
Acc delta speed
Acc delta time
Dec delta speed
Dec delta time
Qstp delta speed
Speed
1
2
1
Acc delta speed [21]
2
Acc delta time [22]
3
Dec delta speed [29]
4
Dec delta time [30]
TPD32 ... 2B
364
[21]
[22]
[29]
[30]
Quick stop
[37]
[38]
No.
min
21
0
22
0
65535
29
0
30
0
65535
37
0
38
0
65535
343
0
Has the same unit as the ramp reference value and is based on the factor function.
Is defined in seconds. The ramp output follows the reference value directly if "0 s" is
entered.
Has the same unit as the ramp reference value and is based on the factor function.
Is defined in seconds. If "0 s" is entered, the ramp output follows the reference value
directly.
Has the same unit as the ramp reference value and is based on the factor function.
Speed
3
4
Time [s]
Figure 6.17.4.1: Acceleration and deceleration
—————— TPD32-EV ——————
Acc delta speed [FF]
Acc delta time [s]
Dec delta speed [FF]
Dec delta time [s]
QStp delta speed [FF]
QStp delta time [s]
Value
Factory
max
American
2
-1
100
32
1
2
-1
100
32
1
2
-1
1000
32
1
1
No Quick stop
3
1
4
2
TPD32 ... 4B
Standard
Factory
Configuration
Standard
100
1
100
1
1000
1
No Quick stop
1
Acc delta speed [21]
2
Acc delta time [22]
3
Dec delta speed [29]
4
Dec delta time [30]
2
1
3
Time [s]
4