OPERATION, INSTALLATION AND MAINTENANCE MANUAL
F l u s h M o u n t E n c l o s u r e
f o r
H e a t s t r i p E l e g a n c e
( T H E R a n g e )

Advertisement

Table of Contents
loading

Summary of Contents for HEATSTRIP THE 1800

  • Page 1 OPERATION, INSTALLATION AND MAINTENANCE MANUAL F l u s h M o u n t E n c l o s u r e f o r H e a t s t r i p E l e g a n c e ( T H E R a n g e )
  • Page 2 Rev B Oct 16 The Flush Mount Enclosure is an ideal way to neatly install the HEATSTRIP into a ceiling. They are available for all HEATSTRIP Elegance models and are supplied as a one-piece unit suitable for mounting individual heaters. Flush mounting can be used with any building grade ceiling materials.
  • Page 3: View From Top

    Flush Mount Enclosure Dimensions VIEW FROM UNDERNEATH VIEW FROM TOP PART No MODEL “A” (mm) “B” (mm) “C” (mm) THEAC-040 THE1800 1080 1024 1020 THEAC-041 THE2400 1310 1254 1250 THEAC-042 THE3600 1910 1854 1850...
  • Page 4: Installation Location

    It is recommended to use only the provided holes in the ends of the enclosure for mounting. Ensure all clearances detailed in the HEATSTRIP ELEGANCE PRODUCT MANUAL are strictly fol- lowed. The diagrams below shows the general location constraints.
  • Page 5: View From Below

    Installation Clearance Dimensions The diagrams below give the minimum clearances installation of the Flush Mount Enclosure. It is recommended to use only the provided holes in the ends of the enclosure for mounting.  The minimum distance between the back of the enclosure and any building material is 150mm. ...
  • Page 6: Installation Instructions

    Installation Instructions MODEL “D” DISTANCE FROM END Ensure all minimum clearance requirements are met and the TO BRACKET (mm) materials used are compliant to your local building codes. THE1800 Before installing the FME, ensure the site to be fixed is fully THE2400 prepared with the hole cut the correct size and the mounting points securely in place.
  • Page 7: Maintenance

    Safety In operation, this heater is VERY HOT— do not touch any part of the heater while it is turned on. Do not touch any part until 30 minutes after it is turned off. This appliance is not intended for use by persons (including children) with reduced physical, sensory or intellectual capabilities, or lack of experience and knowledge, unless they have been given super- vision or instruction concerning use of the appliance by a person responsible for their safety.
  • Page 8: Warranty Terms And Conditions

    Provision of this warranty is subject to:  The HEATSTRIP FME product must be installed in accordance with the Installation Instructions and relevant elec- trical standards and codes.  The HEATSTRIP FME product must be maintained and cleaned according to instructions detailed in the Installa- tion Manual.