HEATSTRIP Design THH Series Operation, Installation, And Maintenance Manual

HEATSTRIP Design THH Series Operation, Installation, And Maintenance Manual

Advertisement

Quick Links

OPERATION, INSTALLATION AND MAINTENANCE MANUAL
H E AT S T R I P I n d o o r
- E U R O P E
T h e h e a t e r t h a t i s a d e s i g n f e a t u r e

Advertisement

Table of Contents
loading

Summary of Contents for HEATSTRIP Design THH Series

  • Page 1 OPERATION, INSTALLATION AND MAINTENANCE MANUAL H E AT S T R I P I n d o o r - E U R O P E T h e h e a t e r t h a t i s a d e s i g n f e a t u r e...
  • Page 2: Table Of Contents

    CONTENTS Rev C Mar16 Product overview Specifications Spot heating principle Selection guide Installation requirements Installation location Mounting options Standard mounting brackets Angle mounting brackets Flush mount enclosure End-to-end mounting bracket Suspension mount bracket T-Bar mount Wall controller with remote Wall controller installation guide Safety &...
  • Page 3: Product Overview

    1,2 3, or 4 enclosed sides or open indoor area’s, with an ideal mounting height of 2.3m to 2.7m. HEATSTRIP Max (THX models) is an ultra high temperature heater used for uncovered or open areas with a mounting height of 2.4 m to 3.5m.
  • Page 4 Heatstrip Indoor — Features & Benefits Stylish, Modern, Sleek, Slimline design The new modern, slimline design of the Heatstrip Indoor makes it the sleekest profile on the market. It will elegantly and seamlessly blend into any indoor environment or décor.
  • Page 5: Specifications

    2.3 m to 2.7 m MAXIMUM 3.0 m (For higher ceiling heights, units can be lowered using optional bracket kits or refer to the Heatstrip Max range) MOUNTING OPTIONS Suitable for ceiling, wall and recess mounting. Also available for suspension chain mount bracket.
  • Page 6: Spot Heating Principle

    The top table shows a comparison between spot heating over a table or heating an entire area. The bottom table shows the flexibility of using HEATSTRIP to provide a comfortable environment even when the layout of the area is unusual.
  • Page 7: Selection Guide

     Ideal mounting location: ceiling mounted, directly above area to be heated (eg. above a table, seating area etc.) The below table outlines the coverage of each HEATSTRIP Indoor model (in m ), based on 2 different scenarios. For example, for an indoor area that is protected, Model THS1200AEU will cover 8m...
  • Page 8: Installation Requirements

    Installation Requirements The ideal mounting position for the HEATSTRIP Indoor is on the ceiling, directly above the area to be heated. If this is not possible, HEATSTRIP Indoor can be mounted on a wall and angled downwards. In this situation, ensure the mounting height is in the range of 2.1m to 3.0m.
  • Page 9: Installation Location

    Installation Location —the below diagrams confirm the minimum recommended clearances. Angled Wall Installation Ceiling Installation Angled...
  • Page 10: Mounting Options

    - refer to below diagrams. The HEATSTRIP Indoor can be mounted directly to the ceiling; angled downwards on a wall; fitted flush with the ceiling; suspended on chains or mounted end-to-end. Refer to the following pages for more detailed information on each mounting option.
  • Page 11: Standard Mounting Brackets

    Standard Mounting Brackets The HEATSTRIP Indoor comes with a pair of standard mounting brackets. These brackets allow direct ceiling mount. The brackets need to be mounted onto a secure frame or ceiling with a minimum distance between the two brackets. The minimum distance (“B”) for each model is listed in the table below.
  • Page 12: Angle Mounting Brackets

    Angle Mounting Brackets The HEATSTRIP Indoor has optional angle mounting brackets. These brackets can be mounted to the ceiling or the wall to bring the effective heat closer to where it is needed. The angle of the bracket is preset to 45 When installing, ensure that the minimum distances are maintained.
  • Page 13: Flush Mount Enclosure

    Flush Mount Enclosure The Flush Mount Enclosure is an ideal way CEILING RECESS to neatly install the Heatstrip Indoor into a ceiling. They are available for all Heatstrip Indoor models, and are supplied as a one- piece unit for mounting of heaters. Flush mounting can used with plaster or wood lined ceiling materials.
  • Page 14: End-To-End Mounting Bracket

    End to End Mounting Bracket The end to end bracket allows multiple units to be joined in a straight line for maximum heat performance and aesthetic appeal. This is ideal for applications such as long rows of tables and assembly lines, where a constant heat coverage is required.
  • Page 15: Suspension Mount Bracket

    Suspension Mount Bracket The Suspension Mount bracket provides a cheap, easy and effective option for lowering the HEATSTRIP Indoor from high ceilings. If the ceiling height is more than 2.7m is an enclosed outdoor environment. It is recommended to lower the heaters to an ideal mounting height of 2.1m—2.7m.
  • Page 16: T-Bar Mount

    T Bar Mount The T Bar Mount is designed to fit as a half tile into a standard 1200 x 600mm T Bar ceiling grid. CEILING An ideal mounting height is 2.1m-2.4m, with a maximum ceiling height of 2.7m in an indoor enclosed environment. Maximum mounting heights should be strictly followed, otherwise the performance of the units may be reduced.
  • Page 17: Wall Controller With Remote

    Wall Controller with remote control This controller is a custom designed and manufactured controller for HEATSTRIP . It has been designed for ease of use to ensure economic running costs of your heater. It provides a timer for automatic heater operation.
  • Page 18: Wall Controller Installation Guide

    Wall Controller Installation Guide WALL SCREW TT-MTR GANG BOX...
  • Page 19: Safety & Maintenance

    Safety HEATSTRIP Indoor has an IP rating of 45. This means it is safe for water ingress from all directions. The HEATSTRIP can be safely hosed down. HEATSTRIP has undergone extensive testing both in laboratory conditions; in Thermofilm’s manufacturing facility in Melbourne and field trials in Australia and overseas.
  • Page 20: Warranty Terms & Conditions

    The below Warranty Terms and Conditions apply for international warranty only. Cook & Heat B.V. warrants to the original owner that HEATSTRIP Indoor products will be free from defects in materials and workmanship for a period of 24 months from the date of purchase in accordance with the following warranty terms and conditions.

Table of Contents