System Configuration

1-2

System Configuration

1-2-1 Device Configuration

Workstation or personal computer
Terminator
Between nodes:
Integral multiples of 2.5 m
Transceiver
50 m max.
Transceiver cable
CS1 Ethernet Unit
Controller Link network
C200HX/HG/HE PC
FA computer

1-2-2 Node Connections

Minimal Configuration: 1 Segment
Configuration With
Segment Extension
CS1 Ethernet Unit
CS1-series PC
CS1 Controller Link Unit
CS1-series PC
Note
1. Transmission distance (from Terminator to Terminator):
500 meters/segment max.
2. When segments are indirectly connected by a repeater: 2.5 km/network
3. Node interval (from transceiver to transceiver): Integral multiples of 2.5 m
4. Transceiver cable length: 50 m max.
Use repeaters to extend the distance between nodes or to increase the number
of connected nodes.
Node
Ethernet (10 Mbps)
500 m/segment max.
10BASE5 coaxial cable
(or 10BASE-T twisted-pair cable)
CS1-series
PC
CS1-series
PC
CX-Programmer
Node
Node
Repeater
Node
Section
CX-Programmer
Terminator
Ground
CVM1/CV-series
PC
CVM1/CV Ethernet Unit
Node
Node
Node
1-2